My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3355
>
2300 - Underground Storage Tank Program
>
PR0508352
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2021 9:09:56 AM
Creation date
6/3/2020 9:59:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0508352
PE
2361
FACILITY_ID
FA0008044
FACILITY_NAME
CHEVRON STATION #1731*
STREET_NUMBER
3355
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12618007
CURRENT_STATUS
01
SITE_LOCATION
3355 E HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508352_3355 E HAMMER_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
492
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer Q Industry Standard ❑ Professional Engineer <br /> E]Other(Spec) <br /> Test Method Used: ®Pressure ❑Vacuum Q Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: See attached testing procedures Equipment Resolution: Inches <br /> Sump# 87 Sump# 91 Sump# Sump# <br /> Sump Diameter: 48" 48" <br /> Sump Depth: 63" 63" <br /> Sump Material: Fiberglass Fiberglass <br /> Height from Tank Top to Top of 12" 12" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 24" 24" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Fair Fair <br /> Portion of Sump Tested' 4"Above highest penetration 4"Above highest penetration <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes❑No Q NA ❑Yes❑No Q NA ❑ Yes ❑No❑NA ❑ Yes ❑No ❑NA <br /> product and water)?* <br /> Turbine shutdown response time N/A N/A N/A N/A <br /> Is system programmed for fail-safe ❑Yes❑No Q NA ❑Yes ❑No Q NA ❑ Yes❑No❑NA ❑ Yes ❑No❑NA <br /> shutdown?* <br /> Was fail-safe verified to be El Yes❑No Q NA ❑ Yes❑No Q NA ❑Yes❑No❑NA ❑ Yes❑No❑NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 minutes 15 minutes <br /> test: <br /> Test Start Time: 9:37am 9:37am <br /> Initial Reading(R,): 0.32065 Inches 0.02566 Inches Inches Inches <br /> Test End Time: 9:52am 9:52am <br /> Final Reading(RF): 0.32067 Inches 0.02509 Inches Inches Inches <br /> Test Duration: 15 mins 15 mins <br /> Change in Reading(RF-Ri): 0.00002 0.00057 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 <br /> Test Result: ✓❑Pass OFail ®Pass ❑Fail ❑Pass ❑Fail []Pass OFail <br /> Was sensor removed for testing? QYes ❑No ❑NA QYes [:]No ❑NA ❑Yes ❑No [INA] ❑Yes []No ❑NA <br /> Was sensor properly replaced and QYes ❑No []NA El Yes E3 No [:INA ❑Yes [:]No [:]NA ❑Yes ❑No [:]NA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up,for failed tests) <br />