Laserfiche WebLink
Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at hftp://www.swrcb.ca.gov.) <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23,California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CHEVRON 208118 N-4087-1-3 Bldg.No.: <br /> Site Address: 3355 E. HAMMER LANE@ HOLMAN RD City: STOCKTON Zip: 95212 <br /> Facility Contact Person: MANAGER Contact Phone No.: 209-477-3699 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 1/17/2018 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment ins ected/serviced: <br /> Tank ID: Ti-SUPREME Tank ID: T2-REGULAR <br /> r In-Tank Gauging Probe. Model: 846390-109 j' In-Tank Gauging Probe. Model: 846390-109 <br /> 170 Annular Space or Vault Sensor. Model: 794390409 r Annular Space or Vault Sensor. Model: 794390-409 <br /> r. Piping Sump/Trench Sensor(s). Model: 794380-208 7 Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> Fill Sump Sensor(s). Model: r Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: r— Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Veeder Root PLLD- [70 Electronic Line Leak Detector. Model: Veeder Root PLLD- <br /> Tank Overfill/High-Level Sensor.Model: flapper Tank Overfill/High-Level Sensor.Model: flapper <br /> Other(specify equipment a and model in Section E on Pae 2). Other(specify equipment a and model in Section E on Pae 2). <br /> Tank ID: Tank ID: <br /> In-Tank Gauging Probe. Model: r In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: r— Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: r Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor.Model: r Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equipment a and model in Section E on Page 2). r, Other(specify equipment a and model in Section E on Pae 2). <br /> Dispenser 1/2 Dispenser 3/4 <br /> ID: ID: <br /> r7 Dispenser Containment Sensor(s).Model: 794380-208 1' Dispenser Containment Sensor(s).Model: 794380-208 <br /> Shear Valve(s). r! Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 5/6 Dispenser 7/8 <br /> ID: ID: <br /> W Dispenser Containment Sensor(s).Model: 794380-208 r�_O Dispenser Containment Sensor(s).Model: 794380-208 <br /> Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). r— Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 9/10 Dispenser 11/12 <br /> ID: ID: <br /> rV Dispenser Containment Sensor(s).Model: 794380-208 f--/ Dispenser Containment Sensor(s).Model: 794380-208 <br /> r Shear Valve(s). r Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). I—, Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply):P System set- <br /> up P Alarm history report <br /> Technician Name(print): Brent Bowen Signature: <br /> Certification No.: B42815 License.No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)800-4633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 1/17/2018 <br /> Monitoring System Certification Page 1 of 3 12/07 <br />