Laserfiche WebLink
Mukai <br />Don*K <br />MECHANICAL ANICAL ENGINEER <br />1841 Paloma St. Pasadena, CA 91104 <br />.323-888.-4136 <br />,lune 1.2010 Rev. 102) 4.11 <br />Mrs, Paola Recendez <br />S. Bravo Systems, Inc. <br />2929 Vail Ave. <br />Commerce:, CA 90040 <br />Roo Specification approved by a state registered professioilai ,engineer <br />CC'R "ritle 23. Division 3, Chapter 16, Article 3, Section 2631(d) <br />This letter is foran engnieering speeification review and approval of a secondary containment <br />system component which is not an integral part of primary containment for an undetground <br />fuel tank storage system in Californias. The authority for this approval comes from the <br />California Code of Regulations (CCR) Title 23, Division 3, Chapter 16, article 3, Section <br />2631(d), <br />I have examined and reviewed the following specifications on the Bravo F -Series fiberglass split <br />retrofit "Retrofit -S" and "Retrofit -Sly -AW fittings: <br />I ) UI. Certifications Directory MII?l 018 for Vipel F-764 and F-774 resins <br />2) AOC Vipe) Product Selection Guide & Corrosion Resistance Guide <br />3) Bravo datzsheets F-Set-ies-SW-IOA, R -Series -DW -100, F -Series -UR -11A, <br />F-Series-D-BLR-S-11 B, F -Series -Retrofit -S-1 I B and F -Series -Retrofit -SD -AB -11 A <br />4) Bravo Installation Manuals ii -F -SERIES -TS -11A. ii -F -SERIES -TS -D-11 A, <br />ii -F -SERIFS -SS -09$, ii -F' -St -RIES -TS -AW -INSERT, ii-ILSEI�IES--IX-SS-IIA.. <br />ii-li-SERII,S-tX-SS' LD -I IA, ii-F-SERIES-LCX:09B, ii-la-SEIZIES-LCX-D-09B, <br />ii -F S-RE'T'ROFIT--S-I OC, ii -FS -RETROFIT -SD -AB -1 OA, ii-SANDKIT I I B <br />5) Bravo Systems `third Party document 3RP-F-Wes and 3RP-FS-FIX-D-BLR-S <br />6) Bravo Systems UL Approval document CUT.-l;Series <br />7) Bravo materia) compatibility tetters Susill)s_AIternativeFuels Rl and <br />Fittings _AltemativeFuels R1 <br />8) Sillith Bulletin D4025. D4010 and B2102 <br />5) Aileron PSX-20 Adhesive Kit - Bondstrand Prodtiet Data FP699B <br />10) Bravo ADHESIVE-EPDXY-KITand ADI-11✓SIVE-RETROFIT-E-IIOXY-Kll, <br />This system provides a bonded reilolit solution to replace. from the inside of•a single Mall tibcrglass <br />containment sump or from both sides of a double wall fiberglass coiltaintlient suilip, a suspcet or <br />failing flexible penetration fitting. This product maintains the integrity of a single walled containment <br />suint) or both tile primary and secondary wall of a dOUble }wall COnt-11illibeilt SUMP iRCluding 1110 <br />.integrity of it's existing interstice by perinatiesltly bondim, the sump wall to the fiberglass pipe or <br />conduit at,c:ach entry point <br />Confittuv(l oi-I 1 agv 3... <br />3RP-FS-RETROFITS PAGE 1 of 2 <br />