Laserfiche WebLink
0 Page 4 of 8 <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: See attached testing procedures <br />Equipment Resolution: <br />Sump # 87 <br />Sump # 91 <br />Sump # <br />Sump # <br />Sump Diameter: <br />48" <br />48" <br />Sump Depth: <br />77" <br />77" <br />Sump Material & Manufacturer: <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />1299 <br />12" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />34" <br />34" <br />Condition of sump prior to testing: <br />Fair <br />Fair <br />Sump <br />Portion of Sum Tested' <br />Above highest <br />penetration <br />Above highest <br />penetration <br />Above highest <br />penetration <br />Above highest <br />penetration <br />Does turbine shut down when <br />sump sensor detectsliquid (both <br />product and water)?* <br />ElYes ❑ No ® NA <br />❑Yes ❑ No ® NA <br />❑Yes ElNo ® NA <br />E]Yes ❑ No ® NA <br />Turbine shutdown response time <br />Is system programmed for fail-safe <br />shutdown?* <br />❑ Yes ❑ No ® NA <br />❑Yes ❑ No ® NA <br />❑Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />Was fail-safe verified to be <br />operational?` <br />❑ Yes ❑ No ® NA <br />❑Yes ❑ No ® NA <br />❑Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />9:44AM <br />9:42AM <br />Initial Reading (RI): <br />0.1570 <br />0.6701 <br />Test End Time: <br />9:59AM <br />9:57AM <br />Final Reading (RF): <br />0.1570 <br />0.6697 <br />Test Duration: <br />15 min <br />15 min <br />Change in Reading (RF -RI): <br />0 <br />0.00045 <br />Pass/Fail Threshold or Criteria: <br />0.002 <br />0.002 <br />0.002 <br />0.002 <br />Test Result: <br />Z Pass '' [:]Fail <br />0 Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />®Yes [1No ❑ NA <br />®Yes ElNo ElNA <br />Yes ❑ No ElNA <br />®Yes [_1No [:1NA <br />Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />I If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />