7. AL -DISPENSER CONT (U ENT ) TESTING Page 6 of 8 <br />Test Method Developed By: ❑ UDC Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: See attached testing procedures. <br />Equipment Resolution: <br />UDC #9/10 <br />UDC #11/12 <br />UDC# <br />UDC# <br />UDC Manufacturer: <br />UDC Material: <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />30" <br />30" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />8" <br />8" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />5" <br />5" <br />Condition of UDC prior to <br />testing: <br />Fair <br />Fair <br />Portion of UDC Tested <br />Above highest <br />penetration <br />Above highest <br />penetration <br />Above highest <br />penetration <br />Above highest <br />penetration <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?. <br />❑ Yes ❑ No ® NA <br />❑Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />Turbine shutdown response time <br />Is system programmed for fail- <br />safe shutdown?* <br />❑ Yes ElNo ®NA <br />❑Yes E]No ®NA <br />El Yes [:1No ®NA <br />[:1 Yes ElNo ®NA <br />Was fail-safe verified to be <br />operational?* <br />r_1 Yes ElNo ®NA <br />❑Yes E]No ®NA <br />F1 Yes F1No ®NA <br />❑Yes ❑ No ®NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />10:52am <br />10:56am <br />Initial Reading (RI): <br />2.2029 <br />2.7237 <br />Test End Time: <br />11:07am <br />ll:llam <br />Final Reading (RF): <br />2.2024 <br />2.7236 <br />Test Duration: <br />15 min <br />15 in <br />15 min <br />15 min <br />Change in Reading (RF -RI): <br />0.00050 <br />0.00010 <br />Pass/Fail Threshold or Criteria: <br />0.002 <br />0.002 <br />0.002 <br />0.002 <br />Test Result: <br />® Pass I ❑ Fail <br />® Pass ❑ Fail <br />❑ Pass ❑ Fail , <br />❑ Pass . ❑ Fail <br />Was sensor removed for testing? <br />®Yes ❑No ❑ NA <br />®Yes [-]No [-INA <br />®Yes ❑No ❑NA <br />®Yes [-]No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />®yes [:]No ❑ NA <br />®Yes ❑No ❑NA <br />ZYes ❑No ❑ NA <br />®Yes ❑No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to M of the questions indicated with an <br />asterisk(*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />