COMPLIANCE INFO_1999-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_1999-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2021 10:06:56 AM
Creation date
6/3/2020 9:59:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2005
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515365_120 FRANK WEST_1999-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
458
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> ® n <br /> TEST DATE:03/26/04 8900 SHOAL CREEK,BUILDING 200 WORK ORDER NUMBER2230464 <br /> CLIENT:TEICHERT CONSTRUCTION AUSTIN,TEXAS 78757(512)451-6334 SITE:TEICHERT CONSTRUCTION <br /> Tank ID: #1 1 Tank manifolded: No Bottom to top fill in inches: <br /> Product: DIESEL Vent manifolded: No Bottom to grade in inches: <br /> Capacity in gallons: 34,788 Vapor recovery manifolded: NO Fill pipe length in inches: <br /> Diameter in inches: 144.00 Overfill protection: YES Fill pipe diameter in inches: <br /> Length in inches: 497 Overspill protection: YES Stage I vapor recovery: NONE <br /> Material: D.P. FIBRE Installed: ATG Stage II vapor recovery: NONE <br /> CP installed on: <br /> COMMENTS <br /> Stant(in) End(in) <br /> Dipped Water Level: New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Product Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Probe Water Level: Make: VAPORLESS VAPORLESS <br /> Ingress Detected: Water Bubble Ullage Model: LD3000 LD3000 <br /> Test time: S/N: 07110 07120 <br /> Inclinometer reading: Open time in sec: 3.00 3.00 <br /> Holding psi: 23 23 <br /> VacuTect Test Type: NOT Resiliency cc: zso zso <br /> VacuTect Probe Entry Point: TESTED <br /> Test leak rate ml/m: 189.0 189.0 <br /> Pressure Set Point: Metering psi: 19 20 <br /> Tank water level in inches: Calib. leak in gph: 3.00 3.00 <br /> Water table depth in inches: Results: PASS PASS <br /> Determined by(method): <br /> Result: <br /> COMMENTS <br /> COMMENTS <br /> Material: DW FIBERG DW FIBERG DW FIBERG <br /> Diameter(in): 2.0 3.0 3.0 <br /> Length(ft): 60.0 25.0 25.0 <br /> Test psi: 5o 50 50 <br /> Bleedback cc: 60 350 350 <br /> Test time(min): 30 30 30 NOT <br /> Start time: 11:00 11:45 11:45 TESTED <br /> End time: 11:30 12:15 12:15 <br /> Final gph: 0.000 0.003 0.003 <br /> Result: PASS PASS PASS <br /> Pump type: PRESSURE PRESSURE PRESSURE <br /> Pump make: RED JACKET UNKNOWN UNKNOWN <br /> COMMENTS Impact Valves Operational: YES <br /> Printed 04/08/2004 16:05 <br />