My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_2006-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2021 1:42:31 PM
Creation date
6/3/2020 9:59:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2009
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRANK WEST\120\PR0515365\SUMP REPAIR 2008.PDF
QuestysFileName
SUMP REPAIR 2008
QuestysRecordDate
11/10/2015 5:47:54 PM
QuestysRecordID
2922518
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
362
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Site Address: 120 FRANK WEST CIRCLE <br />D. Results of Testing/Servicing <br />Software Version Installed: 20.02 <br />Complete the following checklist: <br />'toring System Certification 10 <br />Date of Testing/Service: 03/02/2007 <br />x Yes <br />No * <br />Is the audible alarm operational? <br />❑x Yes <br />No' <br />Is the visual alarm operational? <br />❑x Yes <br />No' <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />Q Yes <br />❑ No <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not <br />interfere with their proper operation? <br />Yes <br />No * <br />x N/A <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? <br />❑x Yes <br />❑ No * <br />❑ N/A <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive <br />shut -down? (check all that apply) ❑ Sumpfrrench Sensors; ❑X Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? ❑X Yes No <br />❑x Yes <br />❑ No' <br />❑ NSA <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (Le.: no mechanical <br />overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill points(s) and operating <br />properly? If so, at what percent of tank capacity does the alarm trigger? so <br />❑ Yes- <br />®No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br />manufacturer name and model for all replacement parts in Section E, below. <br />❑X Yes- <br />®No <br />Was liquid found inside any secondary containment systems designed as dry systems? (check all that apply) ❑ Product; <br />❑x Water. If yes, describe causes in Section E, below. <br />❑x Yes <br />® No * <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set-up reports, if applicable. <br />11:1 Yes <br />Q No * <br />Is all monitoring equipment operational per manufacturers' specifications? <br />* In Section E below, describe how and when these deficiences were or will be corrected. <br />E. Comments: <br />DSL TANK HAS TWO PIPING SUMPS. L-1 SUMP A AND L-2 PIPING SUMP B WITH TURBINE. <br />PUMPED APROX. 3 GALS. OF WATER FROM WASTE OIL AND DSL SUMPS. <br />Page 2 of 3 Based on CA form dated 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.