My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_2006-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2021 1:42:31 PM
Creation date
6/3/2020 9:59:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2009
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRANK WEST\120\PR0515365\SUMP REPAIR 2008.PDF
QuestysFileName
SUMP REPAIR 2008
QuestysRecordDate
11/10/2015 5:47:54 PM
QuestysRecordID
2922518
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
362
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Veeder-Root Line Leak Applicatl Guide <br /> P <br /> Selecting a Line Leak Detector <br /> This guide helps you to properly configure Veeder-Root's line leak equipment for underground pressurized piping. Note: Since <br /> PLLD and WPLLD do not perform leak tests on the pump in all applications,appropriate containment/leak detection <br /> must be provided when selecting either of these leak detectors. <br /> Veeder-Root offers two types of line leak detectors,each uniquely suited to a particular type of application: <br /> • PLLD Pressurized Line Leak Detection <br /> • WPLLD Wireless Pressurized Line Leak Detection <br /> PLLD and WPLLD eliminate the need to break the product line for installation or service. In addition,WPLLD installs without <br /> running new wires. PLLD and WPLLD are the cost-effective choice for most retrofit and new piping installations. <br /> Veeder-Root's electronic line leak detectors have been evaluated by a third party in accordance with EPA evaluation proce- <br /> dures. Please refer to the test reports in Veeder-Root manual numbers 576013-308 and 576013-866 for the results of these <br /> evaluations. <br /> r r <br /> LINE LEAK DETECTION <br /> 3 gph Testing YES YES <br /> Precision Testing OPTIONAL OPTIONAL' <br /> Positive Shutdown YES YES <br /> 3rd Party Certified YES YES <br /> INSTALLATION REQUIREMENTS <br /> Requires TLS Console YES YES <br /> Installs Without Breaking Piping YES YES <br /> Installs Without New Sump YES YES <br /> Installs Without New Wires NO YES <br /> 'Not available for flexible piping <br /> Line Leak Specifications - Supported Pump Models (Footnotes explained at end of table' <br /> r r ® e <br /> P75U1RJ1-RJ3,AGP75S1RJ1-RJ3(3/4 HP) YES YES <br /> P150U1RJ1-RJ3,AGP150SIRA-RJ3(1-1/2 HP) YES YES <br /> THE RED JACKET X3P150U1RJ1-RJ3,X3AGP150S1RJ1-RJ3(1-1/2 HP) YES YES <br /> P20001-3RJ1-RJ3,AGP200S1RJ1-RJ3(2 HP) YES YES <br /> P33U1 QS1-QS3,AGP33S1 QS1-QS3(1/3 HP) YES YES <br /> P75U1Y QS1-QS3,AGP75SIY QS1-QS3(3/4 HP) YES YES <br /> QUANTUM P150U1Y QS1-QS3,AGP15OSlY QS1-QS3(1-1/2 HP) YES YES <br /> RED JACKET X3P150U1Y QS1-QS3,X3AGP150S1Y QS1-QS3(1-1/2 HP) YES YES <br /> X5P150U1Y QS1-QS3,X5AGP150S1Y QS1-QS3(1-1/2 HP) NO NO <br /> P20001-3Y QS1-QS3,AGP200S1-3Y QS1-QS3(2 HP) YES YES <br /> P33R1 T1-T4(1/3 HP) YES YES <br /> P75S1 Tt-T4(3/4 HP) YES YES <br /> STANDARD P1 50S1 T1-T4(1-1/2 HP) YES YES <br /> X31311 50S1 T1-T4(1-1/2 HP) YES YES <br /> X5P150S1 T1-T4(1-1/2 HP) NO NO <br /> STP33,STPAG33(1/3 HP) YES YES <br /> STP75,STPAG75(3/4 HP) YES YES <br /> FE PETRO STP150,STPAG150,STPAGH150(1-1/2 HP) YES YES <br /> STP200,STPAG200,STPMR200,STPR200(2 HP) YES YES <br /> STPH2O0,STPAGH2O0,STPHMR200,STPHR200(2 HP) YES YES <br /> 585-13(1/3 HP) YES NO <br /> TOKHEIM 585-34(3/4 HP) YES NO <br /> 585-150(1-1/2 HP) YES NO <br /> BENNETT ALL YES NO <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.