My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2023 3:11:49 PM
Creation date
6/3/2020 9:59:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515365_120 FRANK WEST_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ATEICHERT & SON INC* 120 FRANK WEST CIR, STOCKTON September 07, 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br /> An approved underground storage tank (UST) monitoring plan is not current in California Environmental Reporting <br /> System(CERS). Beneath Record keeping for all three tanks, change"yes" to"no"for Tank Integrity Testing Results; <br /> and change"no"to"yes" for Equipment Maintenance and Calibration Records. For tanks C-1 and C-2, beneath <br /> Under Dispenser Containment(UDC) Monitoring, change the UDC Leak Sensor Model to 208 sensor. Immediately <br /> log into CERS, update the required information, and submit for review by the Environmental Health Department <br /> (EHD). <br /> This is a minor violation. <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan. <br /> The Response Plan is not current. Under Section IV RESPONSIBLE PERSONS, remove Steve Edel's name since he <br /> has retired. <br /> This is a minor violation. <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The diesel north submersible turbine pump (STP) sump 208 sensor was found lying down and was not capable of <br /> detecting a leak at the earliest opportunity. Monitoring equipment shall be maintained to be able to detect a leak at <br /> the earliest possible opportunity. The service technician placed t he 208 sensor at the lowest point in the diesel north <br /> STP sump. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 314 HSC 25290.1, 25290.2, 25291 Failed to have secondary containment or secondary containment not tight. <br /> Approximately one-quarter cup of liquid was found in the diesel south submersible turbine pump (STP) sump, <br /> 87-product STP sump, diesel north STP sump; approximately one cup of liquid was found in the under dispenser <br /> containment (UDC) 3/4 sump; and approximately one-half cup of liquid was found in the waste oil fill sump. The <br /> service technicians removed the liquid at the time of the inspection. Continue to monitor the sumps and if the liquid <br /> returns, immediately contact a properly licensed, trained, and certified contractor to address the water intrusion <br /> under permit and inspection of the Environmental Health Department. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> During the testing of the 5.0 horse power diesel line leak detector, there was a release of approximately five gallor <br /> of diesel onto the concrete near dispensers 1/2 and 3/4. The Teichert crew immediately contained the spread of <br /> the diesel and removed all of the product for the concrete, then scrubbed the concrete and placed all of the <br /> hazardous waste into a 55-gallon drum labeled Hazardous Waste. Because of the spill and the illness of the <br /> service technician, testing of the 5.0 horse power diesel line leak detector was not completed today. The facility <br /> will reschedule the testing for another day. <br /> Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.