My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2023 3:11:49 PM
Creation date
6/3/2020 9:59:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515365_120 FRANK WEST_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sagov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility A Teichert & Son Inc. Facility120 Frank West Cir., Stockton Inspection Se 12, 2013 <br />Name: Address: Date: p <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />ROUTINE ANNUAL INSPECTION AND MONITORING SYSTEM CERTIFICATION <br />Class I I violation: (303, 311) <br />303. The diesel annular sensor was found not located at the bottom of the tank to detect a leak at the <br />earliest opportunity. The wrap around sensor was calculated to be short by 8 inches. (According to the <br />tank set up, the tank diameter is 118 inches. The riser was measured at 593/4 inches. The calculations <br />indicate the annular should be 245 inches, but it was measured at 237 inches.) Monitoring equipment <br />shall be maintained to be able to detect a leak at the earliest possible opportunity. The sensor was <br />relocated at the time of inspection. <br />REPEAT VIOLATION <br />311. The bulk delivery diesel line leak detector failed to detect a leak when tested. All line leak <br />detectors shall be capable of detecting a 3 -gallon per hour leak at 10 psi. Immediately have a properly <br />licensed, trained, and certified contractor repair or replace the failed leak detector (LG 113-x listed, if <br />applicable) and obtain a permit within one business day from the EHD. If the failed leak detector can't <br />be replaced immediately, there is a possibility that the diesel UST system may be red tagged to prevent <br />fuel inputs. <br />REPEAT VIOLATION <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD by October 12, <br />2013, along with a statement documenting the corrective actions that have been or will be taken for each <br />violation, and any supporting paperwork. <br />Provided: Return to Compliance Certification form <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACIL S SUBJECT TO REINSPECTION AT ANYTIME AT EHD'S CURRENT HOURLY RATE. <br />EHD 23-0 Rev 04/1 EI2 Orf Page 3 UST INSPECTION REPORT <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Heatth and SafetyCode; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M7) <br />Other Violations <br />999 <br />1 1 1 10ther: <br />See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />ROUTINE ANNUAL INSPECTION AND MONITORING SYSTEM CERTIFICATION <br />Class I I violation: (303, 311) <br />303. The diesel annular sensor was found not located at the bottom of the tank to detect a leak at the <br />earliest opportunity. The wrap around sensor was calculated to be short by 8 inches. (According to the <br />tank set up, the tank diameter is 118 inches. The riser was measured at 593/4 inches. The calculations <br />indicate the annular should be 245 inches, but it was measured at 237 inches.) Monitoring equipment <br />shall be maintained to be able to detect a leak at the earliest possible opportunity. The sensor was <br />relocated at the time of inspection. <br />REPEAT VIOLATION <br />311. The bulk delivery diesel line leak detector failed to detect a leak when tested. All line leak <br />detectors shall be capable of detecting a 3 -gallon per hour leak at 10 psi. Immediately have a properly <br />licensed, trained, and certified contractor repair or replace the failed leak detector (LG 113-x listed, if <br />applicable) and obtain a permit within one business day from the EHD. If the failed leak detector can't <br />be replaced immediately, there is a possibility that the diesel UST system may be red tagged to prevent <br />fuel inputs. <br />REPEAT VIOLATION <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD by October 12, <br />2013, along with a statement documenting the corrective actions that have been or will be taken for each <br />violation, and any supporting paperwork. <br />Provided: Return to Compliance Certification form <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACIL S SUBJECT TO REINSPECTION AT ANYTIME AT EHD'S CURRENT HOURLY RATE. <br />EHD 23-0 Rev 04/1 EI2 Orf Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.