My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2023 3:11:49 PM
Creation date
6/3/2020 9:59:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515365_120 FRANK WEST_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />UNDERGROUND T E TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />FNa <br />-l"A Teichert & Son Inc. Facility 120 Frank West Cir., Stockton Inspection Sep 13, 2012rne: Address: Date: <br />VIOLATIONS <br />C1 <br />C2 <br />M Code Section <br />HSC = CA Health and SafetyCode; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 Other: See attached "Continuation – Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />ROUTINE ANNUAL INSPECTION AND MONITORING SYSTEM <br />Class II violations: (303) <br />303. The used oil sump sensor was found hanging from the inside ledge of the sump, several feet from <br />the bottom of the sump, and not located to detect a leak at the earliest opportunity. Monitoring <br />eq uipment shall be maintained to be able to detect a leak at the earliest possible opportunity. The <br />sensor was relocated to the lowest point of the sump at the time of inspection o <br />-tpS W Cno i G —1d Ca �c ��� /' <br />e Pckn NCiun �C" <br />Notice to Comply - Minor violations: (310) ,, '� p S� <br />OL, <br />310. Liquid was observed in both diesel STP sumps - approximately 1 gallon in the south sump and <br />gallon in the north sump. If water could enter into the secondary containment by precipitation or <br />infiltration, it must be removed and disposed of properly. Immediately remove this liquid, make a <br />hazardous waste determination per Title 22 hazardous waste regulations, and manage it accordingly. <br />Ensure that the sumps are maintained free of liquid. <br />Complete and submit a copy of the Return to Compliance Certification to the EHD by October 13, 2012, <br />along with a statement documenting the corrective actions that have been or will be taken for each <br />violation and any supporting paperwork. <br />Note: The 87 spill container failed initial testing. The cap was replaced, then the bucket was retested <br />and passed. f - <br />�fLe r <br />es I� �1\Ce sc� 11C (�e t `s� `�a 5Q Gv t :'s <br />G,t\ Tj l bow)®ct�C `�� c�trc�nMQfS- � <br />Provided: Return to Compliance Certification form Ur will Cduef cdSU It , t^'� <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD 23-02 <br />Page 3 <br />UST INSPECTION REPORT <br />SAS 1 f`\ <br />GA <br />'Au t -e <br />
The URL can be used to link to this page
Your browser does not support the video tag.