COMPLIANCE INFO_2010-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2023 3:11:49 PM
Creation date
6/3/2020 9:59:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515365_120 FRANK WEST_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITC#ING SYSTEM CERTIFWATION <br />MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS -350 <br />CERTIFICATION / TEST DATE: September 8, 2011 <br />Al. FACILITY A2. OWNER <br />Name Teichert Mobile Equipment Name Teichert Construction <br />Address 120 Frank Circle, Stockton, CA 95206 Address 8833 Kiefer Blvd., Sacramento, CA 95826 <br />Phone # 916-366-8631 Phone # 916-386-3767 <br />Contact Steve Schamaun Contact Steve Schamaun <br />A3. C U P A A4. TESTING CONTRACTOR <br />Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br />Address 600 E. Main Street, Stockton, CA 95202 Address P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified September 1 , 2011 Lic # 617238 A, B, Haz <br />Inspector Stacy Rivera Contact Dulcinea Covan <br />Phone # 209-468-8257 Phone # 916-373-1166 <br />B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br />R•I • TANKS <br />R9• UISPFNStFrS/l1UG'S <br />Dispenser # : 1-2 <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 <br />■ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : 3-4 <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 <br />■ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Tank #1 (Product): Diesel #1 - Sump #1 <br />Tank #1 (Product): Diesel #2 - Sump #2 <br />Dispenser <br />❑ <br />❑ <br />❑ <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />■ <br />Annular Space or Vault Sensor <br />Model: <br />0794390-409 <br />❑ <br />Annular Space or Vault Sensor <br />Model: <br />■ <br />Piping Sump / Trench Sensor(s) <br />Model: <br />0794380-208 <br />■ <br />Piping Sump / Trench Sensor(s) <br />Model: <br />0794380-208 <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />■ <br />Electronic Line Leak Detector <br />Model: <br />0848480-001 <br />■ <br />Electronic Line Leak Detector <br />Model: <br />0848480-001 <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />Tank #3 (Product): Waste Oil <br />Tank #2 (Product): Gasoline - 87 <br />■ <br />In -Tank Gauging Probe <br />Model: <br />0847390-109 <br />■ <br />In -Tank Gauging Probe <br />Model: <br />0847390-109 <br />■ <br />Annular Space or Vault Sensor <br />Model: <br />0794390-409 <br />■ <br />Annular Space or Vault Sensor <br />Model: <br />0794390-409 <br />■ <br />Piping Sump / Trench Sensor(s) <br />Model: <br />0794380-208 <br />❑ <br />Piping Sump / Trench Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />■ <br />Fill Sump Sensor(s) <br />Model: <br />0794380-208 <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />■ <br />Electronic Line Leak Detector <br />Model: <br />0848480-001 <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />■ <br />Tank Overfill / High -Level Sensor <br />Model: <br />0847390-109 <br />■ <br />Tank Overfill / High -Level Sensor <br />Model: <br />0847390-109 <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />R9• UISPFNStFrS/l1UG'S <br />I <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): <br />■ Svstem set-up ■ Alarm History Report <br />WALTON <br />Signature: ENGINEERING. INC <br />Technician / Cert #: Gerardo Guzman / B35394 5242481 -UT Date: September 8, 2011 <br />Dispenser # : 1-2 <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 <br />■ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : 3-4 <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 <br />■ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser <br />❑ <br />❑ <br />❑ <br /># : <br />Dispenser Containment Sensor(s) Model: <br />Shear Valves <br />Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />I <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): <br />■ Svstem set-up ■ Alarm History Report <br />WALTON <br />Signature: ENGINEERING. INC <br />Technician / Cert #: Gerardo Guzman / B35394 5242481 -UT Date: September 8, 2011 <br />