0 0 <br />SWRCB January 2002 Page of <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. (California Code of Regulations, Title 23, Section 2637(aX6)1 <br />4. TANK ANNULAR TESTING <br />Test Method Developed By: <br />x Tank Manufacturer <br />❑ Industry Standard ❑ Professional Engineer <br />❑ Other (4waft) <br />Test Method Used <br />❑ Pressure <br />x Vacuum <br />❑ Hydrostatic <br />❑ Other (Specify) <br />Test Equip Used: Dwyer Manometer <br />Equipment Resolution: +/- 2% <br />Tank # 1 <br />Tank # 2 <br />Tank # 3 <br />Tank # <br />Is Tank Exempt From Testing?' <br />❑ Yes x No <br />❑ Yes x No <br />❑ Yes x No <br />C Yes ❑ No <br />Tank Capacity: <br />35,000 <br />15,000 <br />2,000 <br />Tank Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Tank Nlauufacturer. <br />Xeres <br />Xeres <br />Xeres <br />Product Stored: <br />Diesel <br />Gas <br />Waste Oil <br />Wait time between applying <br />pressure/vacuum/water and <br />30 min <br />30 min <br />30 min <br />30 min <br />startin test: <br />Test Stmt Time: <br />9:45 <br />11:30 <br />12:45 <br />Initial Reading (R1): <br />7.0 <br />7.14 <br />7.24 <br />Test End Time: <br />10.45 <br />1230 <br />1:45 <br />Final Reading (RF): <br />6.98 <br />7.10 <br />7.16 <br />Test Duration: <br />1 hour <br />1 hour <br />I hoer <br />1 hour <br />Change in Reading (RF -R,): <br />.02 <br />.04 <br />.08 <br />Pass/Fail Threshold or Criteria: <br />No less than I" <br />No less than I" <br />No less than I" <br />No less than 1" <br />Test Resalt <br />x Paw ❑ Fail <br />x Pass ® Fail <br />x Pass ❑ Fail <br />❑ . Pass ❑ Fail <br />Was sensor removed for <br />x Yes ❑ No ❑ NA <br />x Yes ❑ No 0 N <br />x Yes 0 N 0 N <br />x Yes ❑ No DNA <br />Was sensor properly replaced and <br />x Yes ❑ No ❑ NA <br />x Yes ❑ No ❑ NA <br />x Yes ❑ No ❑ NA <br />x Yes ❑ No ❑ NA <br />verified functional after ? <br />Comments — (anclude 0foTwation on repairs made prior to testing, and recommended follow-up for failed tests) <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. (California Code of Regulations, Title 23, Section 2637(aX6)1 <br />