My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2023 3:11:49 PM
Creation date
6/3/2020 9:59:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515365_120 FRANK WEST_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br />CERTIFICATION /TEST DATE: September 17, 2018 <br />Al. FACILITY A2. OWNER <br />Name Teichert Mobile Equipment Name Teichert Construction <br />Address 120 Frank Circle , Stockton, CA 95206 Address P.O. Box 15002, Sacramento, CA 95851 <br />Phone # 916=366-8631 Phone # 916-386-3767 <br />Contact Steve Schamaun III Contact Steve Schamaun <br />D. RESULTS OF TESTING / SERVICING <br />Make /Model of Monitoring System: Veeder-Root TLS -350 <br />Software Version Installed: 328.03 <br />Complete the following checklist: <br />SN# <br />■ <br />Yes <br />❑ <br />No* <br />Is the audible alarm operational? <br />■ <br />Yes <br />❑ <br />No* <br />Is the visual alarm operational? <br />■ <br />Yes <br />❑ <br />No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />■ <br />Yes <br />❑ <br />No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br />will not interfere with their proper operation? <br />■ <br />Yes <br />❑ <br />No* <br />if alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modems) <br />❑ <br />NIA <br />operational? <br />■ <br />Yes <br />❑ <br />No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />❑ <br />N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shutdown? (check all that apply) ■ Sump/Trench sensors; ■ Dispenser Containment Sensors. <br />■ <br />Yes <br />❑ <br />No * <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? <br />■ <br />Yes <br />❑ <br />No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />❑ <br />N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? 90% <br />❑ <br />Yes * <br />■ <br />No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />■ <br />Yes * <br />❑ <br />No <br />Was any liquid found inside any secondary containment systems designed as dry systems? <br />(Check all that apply) ❑ Product; ■ Water. If yes, describe causes in Section E, below. <br />■ <br />Yes <br />❑ <br />No* <br />Was monitoring system set-up reviewed to insure proper settings? Attach set-up reports, if applicable. <br />■ <br />Yes <br />❑ <br />No * <br />Is all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. COMMENTS <br />Removed a small amount of water from the Waste Oil fill sum <br />Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.