Laserfiche WebLink
ANNUAL SILL CONTAINER TESI&REPORT <br />TEST DATE: September 24, 2010 <br />Al. FACILITY <br />A2. OWNER <br />Name <br />Teichert Mobile Equipment <br />Name <br />Teichert Construction <br />Address <br />120 Frank Circle, Stockton, CA 95206 <br />Address <br />8833 Kiefer Blvd., Sacramento, CA 95826 <br />Phone # <br />916-366-8631 <br />Phone # <br />916-386-3767 <br />Contact <br />Steve Schamaun <br />Contact <br />Steve Schamaun <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Name <br />Walton Engineering, Inc. <br />Address <br />600 E. Main Street, Stockton, CA 95202 <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />September 15, 2010 <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Ray Von Flue <br />Contact <br />Dulcinea Covan <br />Phone # <br />209-468-8257 <br />Phone # <br />916-373-1166 <br />K. SPILL CONTAINER TEST RESULTS <br />used: ualdweli <br />Tank Number <br />Product contained <br />Spill container capacity (US gallons) <br />Spill container manufacturer <br />Spill container depth (inches) <br />Is the spill container located in a sump? <br />Does sump have a liquid sensor installed? <br />Condition of spill container prior to testing <br />Portion of spill container tested <br />Depth of water level from bottom (inches) <br />Wait time for water level to stabilize (hr:min) <br />Test start time <br />Test end time <br />Test duration (hr:min) <br />Change in water level (± 0.000 inches) <br />Pass/Fail threshold (0.005 inches /'/z Hr.) <br />TEST RESULT <br />I <br />L. COMMENTS: <br />1 <br />Diesel #1 <br />5 <br />CNI <br />16.00 <br />Yes <br />No <br />Dry <br />Entire <br />14.50 <br />0:10 <br />9:19 <br />9:49 <br />0:30 <br />0.000 <br />0.005 <br />PASS <br />The 87 SC failed at the gasket underneath the nipple. <br />Signature: W <br />Technician: Jessie Wadkins / B35391 5307886 -UT <br />n W.4— Fnni... A n 11nr <br />2001 / Walton Engineering (Level Change Indicator) <br />WALTON <br />ENGINEERING, INC. <br />3 <br />Gasoline - 87 <br />5 <br />CNI <br />15.50 <br />Yes <br />No <br />Dry <br />Entire <br />14.00 <br />0:10 <br />9:11 <br />9:41 <br />0:30 <br />0.010 <br />0.005 <br />FAIL <br />4 <br />Waste Oil <br />5 <br />CNI <br />15.50 <br />Yes <br />Yes <br />Dry <br />Entire <br />14.00 <br />0:10 <br />11:21 <br />11:51 <br />0:30 <br />0.000 <br />0.005 <br />PASS <br />Date: September 24, 2010 <br />