Laserfiche WebLink
. <br />TANK# <br />40 <br />16. _ <br />Tanks <br />subject to floatati [Section 2635 (a) (7)] <br />A. Anchored by deadman or slab. <br />MANUFACTURER <br />B. Anchors to be installed as specified by manufacturer. <br />SYSTEM TYPE * <br />C. Installation details provided on plans. <br />m <br />VOL) LZ <br />MATERIAL *** <br />D. Calculations provided. <br />17. SPILL AND <br />OVERFILL PREVENTION <br />100% METHANOL COMPATIBILITY <br />Underground storage tank equipped with spill container and an overfill prevention system. (detail drawing of spill <br />CORROSION PROTECTION <br />container(s)/piping sump(s) required, including tank fill and all openings). <br />A. <br />Spill container [Section 2635 (b) (1)]. <br />_ <br />If made of metal, exterior wall protected galvanic corrosion. <br />--from <br />Capacity: (minimum of five gallons) A -A ZPJ <br />Equipped with a valve which allows drainage of spill into primary container. <br />/drain <br />�✓ <br />Manufacturer: <br />B. <br />Overfill prevention system does not allow for manual override and meets one of the following requirements: <br />(1) Alert transfer operator at 90% full by restricting the flow into the tank or triggering an audible <br />_ <br />and visual alarm [Section 2635(b)(2)(A)] . <br />Manufacturer: Model: <br />(2) Restrict delivery flow to the tank 30 minutes before overfill when tank is filled at no more than <br />f e <br />95% capacity and activates an audible alarm at least five minutes before overfill [Section 2635 <br />(b) (2) (B)]. <br />Manufacturer Model: <br />than 95% capacity [Section 2635 (b) (2) (C)]. <br />_ <br />(3) Provide positive shutoff at no more <br />Model: <br />Manufacturer: <br />(4) Provide positive shut-off of flow to the tank so that the fittings on top of the tank are not <br />exposed to the product overfilling [Section 2635 (b) (2) (D)]. <br />Manufacturer: Model: <br />18. PIPING <br />INFORMATION <br />PIPING INFORMATION <br />TANK# <br />TANK# <br />TANK# <br />TANK# <br />DISTANCE from <br />DISPENSER to TANK <br />MANUFACTURER <br />dT- <br />SYSTEM TYPE * <br />CONSTRUCTION ** <br />m <br />VOL) LZ <br />MATERIAL *** <br />LEAK DETECTION SYSTEM <br />100% METHANOL COMPATIBILITY <br />YES NO <br />CORROSION PROTECTION <br />YES NO <br />* System Type; suction, pressure, and gravity <br />** Construction: single -walled, double -walled, lined -trench, etc. <br />*** Material Type; steel with cathodic protection, stainless-steel, fiberglass reinforced plastic. <br />h <br />