My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1330
>
2300 - Underground Storage Tank Program
>
PR0515864
>
COMPLIANCE INFO_2000-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2024 2:09:22 PM
Creation date
6/3/2020 9:59:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2009
RECORD_ID
PR0515864
PE
2361
FACILITY_ID
FA0012355
FACILITY_NAME
A&A GAS FOOD MART
STREET_NUMBER
1330
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120053
CURRENT_STATUS
01
SITE_LOCATION
1330 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515864_1330 E YOSEMITE_2000-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P4/18/2000 10:30 2094683433 FIFTH FLOOR PAGE 09 <br />19. Piping <br />• <br />(cress- including <br />sectionalram, connections to tank and dispc;-.ers). <br />(A) Vent and cank riser primary containment system equipped with overfill prevention system that: <br />_ <br />Restricts delivery of flow to tank (Section 2635 (b) (2) (8) or (C)I, or <br />Provide positive shut off of flow to the tank at nc more than 45 % [Section 2635 (b)(2)(03, or <br />Cs) <br />vapor recovery piping designed so it cannot contain liquid phase product, or <br />(C) 1 <br />Suction piping (below grade piping operates at less than atmospheric pressure) [Section 2636 (a) (3)1 <br />_ Sloped so contents of the pipe wilt drain back into the storage tank if the suction is <br />released. <br />_ No valves or peurrps installed below grade. <br />_ Inspection method provided to demonstrate compliance with section 2636 (a) (3). <br />CO) <br />Corrodible underground piping protected against corrosion (Section 2636 (b)). <br />(E) <br />Underground primary piping wilt meet all of the following requirements <br />Primary piping in contact with hazardous substance under nornat o ration conditicns shall be: <br />installed inside a secondary containment system in the form of: secondary pipe Vault or <br />Lined trench to be sloped to a eotteetion sump at the low t of the piping. <br />Primary piping and secondary containment systems will be installed in accordance with industry <br />code of practice and voluntary consensus standards.. <br />_ Lined trench used as secondary containment <br />_ Hateriat compatible with the substance stored. <br />_ Covered and capebte of supporting any expected vehicular traffic. <br />(F) Underground piping with secondary containment will be equipped and monitored as follows: <br />Secondary containment will be equipped with a continuous monitoring system connected to an audible <br />and visual alarm system. <br />Automatic tine leak detectors wilt be instaLtAw on pressu ized piping <br />Marufacturer:��M Model:_ <br />annual monitoring witt, be conducted on the pressurized piping with secondary containment. <br />Annual tine tightness test wilt not be required if the continuous monitor shuts down the perp and <br />activates the alarm system when a release is detected and when the continuous monitoring system <br />fails or is disconnected. <br />Re <br />20. State Watersources Control Board "Facility (A)" and "Tank Permit CB)" application forms submitted. <br />21. Plan review and operating permit fees paid_ <br />22. What is the approxie'�ate depth to ground water: <br />(include source of information - borehole logs, monitoring well data, water <br />studies, etc.) <br />23. Total n amber of tanks on site after installation: <br />24. County/City Fire District and Building Department notified. <br />25. In the event contamination is observed, confirmed or suspected as a result of a leaking UST system it is your <br />responsibility (in accordance with (CCR) Title 23, Division 3, Chapter 16, Article 11, Corrective Action <br />Requirements] as an owner or operator to submit a workptan to PHS-EHD Site Mitigation Unit prior to initiating any <br />assessment or re iation activities. For further assistance ccntact the Site Mitigation Unit at (209) 469.3450. <br />The owner o atom must acknowledge this responsility for workptan submittal by signature <br />and date below. <br />Name 4itle //At`f Date <br />COwDITIONS OF APPROVAL: <br />0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.