My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1330
>
2300 - Underground Storage Tank Program
>
PR0515864
>
COMPLIANCE INFO_2000-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2024 2:09:22 PM
Creation date
6/3/2020 9:59:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2009
RECORD_ID
PR0515864
PE
2361
FACILITY_ID
FA0012355
FACILITY_NAME
A&A GAS FOOD MART
STREET_NUMBER
1330
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120053
CURRENT_STATUS
01
SITE_LOCATION
1330 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515864_1330 E YOSEMITE_2000-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The `96 LD -2000 is the newest generation of the most advanced system of <br />mechanical line leak detectors available. For 1996, the LD -2000 becomes even <br />more versatile. One leak detector for virtually any submersible pump, fuel, or line! <br />A patented, internal, free-floating check valve positioned at the downstream end of <br />the leak detector protects the leak detector against damage caused by hydraulic <br />hammer (a rebounding pressure wave formed when the dispenser nozzle is <br />closed). The check valve also maintain line pressure, sufficient to allow dispensa- <br />tion of fuel immediately, providing that the downstream dispensing line has no <br />leak. <br />• One leak detector for any fuel: gasoline, diesel, alcohol <br />• For any pipe/fine system up to 250 ml. bleed back <br />• One leak detector for Red Jacket, FE Petro, or Tokheim submersible pumps <br />• Lowest profile leak detector available for those tight locations <br />• Maintains pressure in the delivery fine when no leak is present <br />• Detects leaks even if substantial hydrostatic shock occurs in the dispensing <br />line <br />• Reduces unscheduled pump maintenance due to check valve deterioration or <br />functional element deterioration <br />• Provides improved performance under extreme climactic conditions <br />• Best performance warranty in the industry, 3 GPH at 10 psi for 24 months <br />after date of installation <br />• Overcomes problems caused by thermal contraction and fine resiliency in <br />larger delivery systems <br />• The `96 LD -2000 exceeds the EPA regulations that require detection of a 3 <br />GPH leak at 10 psi. Under conditions of thermal expansion or contraction, <br />the `96 LD -2000 is capable of detecting a 3 GPH leak with a probability of <br />detection of 100% and a false alarm probability of 0%. <br />• Under neutral test conditions, the `96 LD -2000 detected leaks under 2 GPH. <br />• From pump start-up, the average leak sensing time to full flow was less than <br />5 seconds for pipe lines with up to 250 ml bleed back. <br />• The `96 LD -2000 detected leaks in the pipe system up to 10' above the leak <br />detector. This test, called a "Head Pressure Reset Test," ensures that all <br />buried pipe is protected. <br />• Compatible with <br />...100% gasoline, methanol, and ethanol <br />...Any combination of the above <br />...100% diesel <br />...Up to 15% MTBE <br />...Kerosene/jet AQP 4 <br />• Use with any line/pipe system up to 250 ml <br />bleed back <br />• For use with any UL listed pumps: X h.p., X h.p., <br />and 1 X h.p — 20-50 psi, volume to 90 GPM <br />• Certified to handle 10+ feet of head pressure <br />• Combination line check/pressure relief, prevents <br />drainback into the tank <br />• Hardened 17-4 stainless steel metering pin <br />and poppet <br />• Unique upper cylinder piston functions without <br />a pressure relief <br />• Tamper -proof bolts accommodate wire seal <br />to prevent tampering <br />• For installation in any submersible pump with <br />a 2 inch NPT port, or a 2 inch leak <br />detector adaptor tee <br />• Leak detector is nickel -plated, schedule 40 <br />cast iron construction <br />• MIL Spec. #R-83248 Fleurocarbon O-ring <br />• UL listed and certified to meet EPA <br />GPH @ 10 psi performance specifications <br />online systems up to 130 gallons <br />• Vent line must be unobstructed, leak -proof, <br />and connected to an atmospheric port <br />(e.g. tank head space) <br />• For a complete list of materials and <br />other specifications, please contact VMI. <br />• Can be installed in any position <br />Warran"ityati <br />toThe `96 LD -2000 mechanism is fully guaranteed to see a leak of 3 GPH @ 10 psi <br />for a period of 24 months after date of installation. Warranty card and <br />installation instructions included in packaging. <br />
The URL can be used to link to this page
Your browser does not support the video tag.