Laserfiche WebLink
gFIED PROGRAM CONSOLIDATED FOR*G B� TANK: TA0515518 <br /> PR#: PRO515864 <br /> FAC#: FA0012355 <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 2 <br /> VI.PIPING CONSTRUCTION(check all that apply) Page 3 of 7 <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ® 1.PRESSURE ❑ 2.SUCTION ❑ 3.GRAVITY 458 ❑ 1.PRESSURE ❑ 2 SUCTION ❑ 3.GRAVITY 459 <br /> CONSTRUCTION ❑1.SINGLE WALL ❑3.LINED TRENCH ❑ 99.OTHER 460 ❑ 1.SINGLE WALL ❑ 95.UNKNOWN 462 <br /> 0 2.DOUBLE WALL ❑95.UNKNOWN ❑ 2.DOUBLE WALL ❑ 99.OTHER <br /> MANUFACTURER A O SMITH 461 MANUFACTURER 463 <br /> ❑ 1.BARE STEEL ❑ 6.FRP COMPATIBLE w/100%METHANOL ❑ 1.BARE STEEL ❑ 6.FRP COMPATIBLE w/100%METHANOL <br /> ❑ 2.STAINLESS STEEL ❑ 7.GALVANIZED STEEL ❑ 2.STAINLESS STEEL ❑ 7.GALVANIZED STEEL <br /> ❑ PLASTIC COMPATIBLE W/CONTENTS ❑ 95.UNKNOWN ❑ PLASTIC COMPATIBLE W/CONTENTS ❑95.UNKNOWN <br /> ® 4.FIBERGLASS ❑ 8.FLEXIBLE(HDPE) ❑ 99.OTHER ❑ 4 FIBERGLASS ❑ 8.FLEXIBLE(HDPE) ❑99.OTHER <br /> ❑ 5.STEEL W/COATING ❑9.CATHODIC PROTECTION 464 ❑ 5.STEEL W/COATING ❑ 9.CATHODIC PROTECTION 465 <br /> VII.PIPING LEAK DETECTION(Check all that apply)(A description of the monitoring program shall be submitted to the Iocal agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑ 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF ❑ 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF <br /> FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND <br /> VISUAL ALARMS. VISUAL ALARMS. <br /> ❑ 2.MONTHLY 0.2 GPH TEST ❑ 2.MONTHLY 0.2 GPH TEST ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑4.DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> ❑ 5.DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIEAL PIPING ❑ 5.DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> INTEGRITY TEST(0.1 GPH) ❑ 6.TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): <br /> ❑ 7.SELF MONITORING <br /> ❑ 7.SELF MONITORING <br /> GRAVrrY FLOW <br /> ❑ 9.BIENNIAL INTEGRITY TEST(0.1)GPH GRAVITY FLOW(Check all that apply): <br /> ❑ 8.DAILY VISUAL MONITORING <br /> ❑ 9.BIENNIAL INTEGRITY TEST(0.I)GPH <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) ALARMS AND(Check one) <br /> ❑ a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> IJ��SV,b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM E] b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION <br /> DISCONNECTION <br /> ❑ c. NO AUTO PUMP SHUT OFF ❑ c. NO AUTO PUMP SHUT OFF <br /> 11.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR ❑ 11.AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SU,C170N/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> 43.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Cheek all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF* ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW <br /> SHUT OFF OR RESTRICTION SHUT OFF OR RESTRICTION <br /> ❑ <br /> 16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 16.ANNUAL INTEGRITY TEST(0.I GPH) <br /> ❑ 17.DAILY VISUAL CHECK ❑ 17.DAILY VISUAL CHECK <br /> VIM DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑ 1.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4.DAILY VISUAL CHECK <br /> DATE INSTALLED 468 ❑ 2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5.TRENCH LINER/MONITORING <br /> ® 3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ❑6.NONE <br /> DISPENS +AUDIBLE AND VISUAL ALARMS 469 <br /> IX.OWN R/OPERATOR SIGNATURE <br /> 1 oenify that the infomtation provided herein is true a "Amy ktwwl <br /> SIGNATURE OF OWNER/OPERATO vyDATE \ /) // 470 <br /> NAME OF OPERATgR(print) TITLE OF O ER/OPERATOR <br /> W �&� I <br /> 47I a7z <br /> Permit Number(1p local use only) 473 Permit Approved(For local use only) 474 Permit Expiration Date(For local use only) 415 <br /> PT0011102 EE0000817 12LA nuu&& -NkWAM <br /> UPCF(12/99 revised) <br />