My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1234
>
2300 - Underground Storage Tank Program
>
PR0516248
>
COMPLIANCE INFO_2000-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2023 3:05:39 PM
Creation date
6/3/2020 10:00:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2005
RECORD_ID
PR0516248
PE
2361
FACILITY_ID
FA0012532
FACILITY_NAME
CHEVRON STATION #209167
STREET_NUMBER
1234
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120016
CURRENT_STATUS
01
SITE_LOCATION
1234 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516248_1234 E YOSEMITE_2000-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
onitoring System Certification <br /> Site Address: 1234 YOSEMITE AVE Date of Testing/Service: 06/28/2001 <br /> D. Results of Testing/Servicing <br /> Software Version Installed: <br /> Complete the following checklist: <br /> ® Yes No* Is the audible alarm operational? <br /> ® Yes No* Is the visual alarm operational? <br /> ® Yes No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> Yes No Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not <br /> ® <br /> interfere with their proper operation? <br /> ® Yes ❑No* N/A If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> ® Yes No* ❑N/A monitoring system detects a leak,fails to operate, or is electrically disconnected?If yes:which sensors initiate positive <br /> shut-down(check all that apply) Sump/Trench Sensors; ❑Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due teaks and sensor failure/disconnections M Yes 0 No <br /> ® Yes No* N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no mechanical <br /> overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank fill points(s)and operating <br /> properly? If so,at what percent of tank capacity does the alarm trigger? <br /> E Yes ®No* Was any monitoring equipment replaced?If yes,identify specific sensors, probes,or other equipment replaced and list the <br /> manufacturer name and model for all replacement parts in Section E,below. <br /> Yes ®No* as liquid found inside any secondary containment systems designed as dry systems?(check all that appl jj Product; <br /> Waterlf yes,describe causes in Section E, below. <br /> ® Yes ❑No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports, if applicable <br /> ® Yes R No* Is all monitoring equipment operational per manufacturer's specifications? <br /> *In Section E below,describe how and when these decifiences were or will be corrected. <br /> E. Comments: <br /> page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.