My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1234
>
2300 - Underground Storage Tank Program
>
PR0516248
>
COMPLIANCE INFO_2006-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2023 3:40:58 PM
Creation date
6/3/2020 10:00:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2010
RECORD_ID
PR0516248
PE
2361
FACILITY_ID
FA0012532
FACILITY_NAME
CHEVRON STATION #209167
STREET_NUMBER
1234
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120016
CURRENT_STATUS
01
SITE_LOCATION
1234 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516248_1234 E YOSEMITE_2006-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
433
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page of <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tank Manufacturer ®Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ®Vacuum ❑Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: DIAL GAUGE Equipment Resolution:0 to 15"Hg Vacuum <br /> I� <br /> Tank Tank Tank Tank 1 <br /> Is Tank Exempt From Testing. ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No I <br /> Tank Capacity: GALLONS GALLONS GALLONS GALLONS <br /> Tank Material: Fiberglass Fiberglass Fiberglass Fiberglass <br /> Tank Manufacturer: <br /> Product Stored: 7 G <br /> Wait time between applying <br /> pressure/vacuum/water and 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> starting test: <br /> i <br /> Test Start Time: <br /> Initial Reading W: "HGI O"HG "HG "HG <br /> i <br /> Test End Time: z d ;1_y <br /> Final Reading(RF): `p"HG lo"HG 'HG 'HG <br /> Test Duration: 1 Hour 1 Hour 1 Hour 1 Hour <br /> Change in Reading(RF-RI): 0 -HG a5 "HG "HG "HG <br /> -----Pass/Fail"Threshord-or Criteria: ---- — Zero --Zero ______Zero Zero <br /> Test Result: t•Pass ❑Fail K Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? ❑Yes KNo ❑NA ❑Yes jHNo ❑NAS: ❑Yes❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and <br /> verified functional after testing? Dyes ❑No ®NA Dyes ❑No j&NA' ❑Yes❑No ❑NA ❑Yes ❑No ❑NA <br /> jL <br /> Comments-(include information on repairs rade prior to testing,and recommended fo How-u for failed tests i <br /> I <br /> i <br /> i <br /> i <br /> Chevron #209167 <br /> f 234 YOSOMIte Ave <br /> Manteca, Ca <br /> D8057 SS989 <br /> ! Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23,Section 2637(a)(6)} <br /> IE <br />