Laserfiche WebLink
Work Order: 2250417 <br /> COMMUNICATIONS SETUP <br /> SYSTEM SETUP <br /> J JUN 22, 2007 4:14 FM POxTTTI ' <br /> COMM BOARD 1 (RS-232) <br /> CHEVRON 209167 BAUD RATE 9600 <br /> 1SYSTEM4 YOSEMITE AVE SYSTEM UNITS PARtTY : EVEN <br /> MANTECA CA 95a:' U.S. STOP BIT 1 STOP <br /> SITE 209167 LANGUAGE DATA LENGTH: 7 DATA <br /> RS-232 SECURITY <br /> JUN 22, 2007 4:14 PMYST i DATE/TIME FORMAT C{iDE DI <br /> MON DD YVYY HH:MM:SS -M COMM BOARD : 2 (FXMOD) <br /> } CHEVRON 209167 RATE : 2400 <br /> SYSTE7'I STATUS _ _ 1234 Y 7ITE AVE PARITY : ODD <br /> _ CA 95336 STOP HIT i SLOP <br /> ALL FUNCTIONS NORMAL MAIfITCA SITE 209157 DATA LENGTH: 7 DATA <br /> RS-232 SECURITY <br /> INVENTORY REPORT SHIFT TIME 1 : 5:15 AM CODE : DISABLED <br /> SHIFT TIME 2 : DISARMDIAL TYPE : TONE <br /> SHIFT TIME 3 : DISABLED j AN DEM �' 1�; <br /> T I*xlPFfiIE 5210 GALS SHIFT TLME 4 : DISARM ' <br /> LuAGEVOLLrc - 9766 GALS DIRT- TONE INTERVAL: 32 <br /> ULLACE TANK PER TST NEEDED WRN <br /> %X IFLLAGE4 8268 GALS DISP&MI <br /> TC VOLUME - 5156 CALS TANK ANN TST NEEDED URN { AUTO TRANSMIT S=INGS: <br /> HEIGHT - 44.86 INCHES DISABLED <br /> WATER VOL + 0 GALS AUTO LEAK LIMIT <br /> WATER + 0.00 1 NCHES LINE SHOO' } ISABLED <br /> TPM - 74.6 DEG F PASS LINE TEST AUTO HIGH WATER LIMIT <br /> LINE PER TOT NEEDED WRN i DISABLED <br /> AUTO OVERFiLL LIMIT <br /> VOL REGULAR 13595 GALS LINE TST NEEDED WRN AUTBLED O LOW PRODUCT <br /> ULLAGB - 6108 GALS DISABLED DISABLED <br /> 90% Lt11AG£- 4137 t]A18 AUTO THEFT LIMIT <br /> TC VOLUME 13426 GALS ! PRINT TC VOLUMES DISABLED <br /> HEIGHT 75.86 INCHES ENABLED AUTO DELIVERY START <br /> WATER VOL 0 GALS <br /> DISABLED <br /> WATER - 79 00 INCHES <br /> TEW COMPENSATION AUTO DELIVERY END <br /> TEMP7 DEG P <br /> VALUE (DEG F ): 60.0 <br /> STICK HEIGHT OFFSET DISABLED <br /> DI AUTO EXTERN- INPUT ON <br /> * Hxasx £ND * H # DI <br /> HESAR <br /> IGHT <br /> DATA FORMAT AUTO EXTER►�- INPUT OFF <br /> DISABM <br /> p=1131011 TEST DURATION i AUTO SENSOR FUEL ALARM <br /> RM <br /> HOURS: 12 AUTO SENSOR WATER ALARM <br /> 0.20 GPM LINE TEST <br /> DISARM <br /> AUTO-CONFIRM: ENABLED AUTO SENSOR OUT ALARM <br /> 0.10 GPM LINE TEST DISABLED <br /> AUTO-CONFIRM: ENABLED <br /> DAYLIGHT SAVING TIME <br /> START DATEMAR UM 3 SUN <br /> START TIME RECEIVER SETUP: <br /> 2:00 <br /> :OVATE <br /> NOV WEEK 2 SUN D 6:Solvotw Monthlv Test <br /> END TIM' 18002640422 <br /> 2:00 AM RCM TYPE: FACSIMILE <br /> RE-DIRECT LOCAL PRINTOUT PORT NO: 2 <br /> DISABLED RETRY N0: B <br /> RETRY DELAY: 3 <br /> EURO PROTOCOL PREFIX CONFIRMATION REPORT: OFF <br /> B D B:SOLVONE <br /> 18002626485 <br /> RCVR TYPE: FACSIMILE <br /> SYSTEM SECURITY PORT NO: 2 <br /> CODE000000RETRY NO: B <br /> RETRY DELAY: 3 <br /> CONFIRMATION REPORT: ON <br /> Tanknology Inc. 8501 N.MoPac Expressway,Suite 400,Austin,Texas 78759 <br />