My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1234
>
2300 - Underground Storage Tank Program
>
PR0516248
>
COMPLIANCE INFO_2006-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2023 3:40:58 PM
Creation date
6/3/2020 10:00:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2010
RECORD_ID
PR0516248
PE
2361
FACILITY_ID
FA0012532
FACILITY_NAME
CHEVRON STATION #209167
STREET_NUMBER
1234
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120016
CURRENT_STATUS
01
SITE_LOCATION
1234 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516248_1234 E YOSEMITE_2006-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
433
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
19255517888 Main Fax GETTLER RYAN INC 10:53:15 a.m. 07-13-2007 11/15 <br /> LINE LEAK LOCKOUT SETUP <br /> - - - - - - - - - <br /> LOCKOUT SCHEDULE - - - <br /> LEAK TEST METHOD DAILY <br /> - - - - - - - - - - - - START TIME: DISABLED <br /> TEST ON DATE : ALL TANK STOP TIME DISABLED <br /> JAN 1. 1996 <br /> T 2:REGULAR START TIME : DISABLED <br /> PRODUCT CODE 2 TEST RATE :0.20 GAL/HR <br /> THERMAL COEFF :.000700 DURATION : 2 HOURS <br /> TANK DIAMETER : 120.00 TST EARLY STOP:DISABLED <br /> TANK PROFILE : 4 PTS <br /> FULL VOL : 19703 LEAK TEST REPORT FORMAT <br /> 90.0 INCH VOL : 16357 NORMAL <br /> 60:0 INCH VOL : 10207 <br /> 30.0 INCH VOL : 3941 <br /> i <br /> FLOAT SIZE: 3.0 IN. LIQUID SENSOR SETUP <br /> - - - - - - - - - - - - <br /> WATER WARNING 1 .0 <br /> HIGH WATER LIMIT: 2.0 L I:SUPREME STP SUMP <br /> TRI-STATE (SINGLE FLOAT) <br /> MAX OR LABEL VOL: 19703 CATEGORY : STP SUMP <br /> OVERFILL LIMIT 90/** <br /> 17732 PRESSURE LINE LEAK SETUP <br /> HIGH PRODUCT 95% - - - - - - - - - - - - L 2:REGULAR STP SUMP <br /> 18718 TRI-STATE (SINGLE FLOAT) <br /> DELIVERY LIMIT 10% CATEGORY : STP SUMP <br /> 1970 Q I :SUPREME <br /> LOW PRODUCT 750 TYP:2.0/3.OIN FIBERGLASS L 3:SUPREME ANNULAR <br /> LEAK ALARM LIMIT: 992-01N DIA LEN:415 FEET TRI-STATE (SINGLE FLOAT) <br /> SUDDEN LOSS LIMIT: 99 3.01N DIA LEN: 0 FEET CATEGORY : ANNULAR SPACE <br /> TANK TILT 0.00 0.20 GPH TEST: REPETITIV <br /> 0.10 GPH TEST: AUTO <br /> MANIFOLDED TANKS SHUTDOWN RATE: 3.0 GPH <br /> TO: NONE LOW PRESSURE SHUTOFF:YES L 4:REGULAR ANNULAR <br /> LOW PRESSURE : 10 PSI i TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : ANNULAR SPACE <br /> LEAK MIN PERIODIC: 0% T I :SUPREME <br /> 0 <br /> DISPENSE MODE: <br /> LEAK MIN ANNUAL 0% STANDARD <br /> SENSOR: HIGH PRESSURE L 5:DISP 1-2 <br /> PRESSURE OFFSET: 0.0PSI TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : DISPENSER PAN <br /> PERIODIC TEST TYPE <br /> STANDARD L 6:DISP 3-4 <br /> ANNUAL TEST FAIL TRI-STATE (SINGLE FLOAT) <br /> ALARM DISABLED CATEGORY : DISPENSER PAN <br /> PERIODIC TEST FAIL <br /> ALARM DISABLED <br /> I i <br /> GROSS TEST FAIL L ?:DISP 5-6 <br /> TRI-STATE (SINGLE FLOAT) <br /> ALARM DISABLED Q 2:REGULAR CATEGORY : DISPENSER PAN <br /> ANN TEST AVERAGING: OFF TYP:2.0/3.01N FIBERGLASS <br /> PER TEST AVERAGING: OFF i <br /> 2.01N DIA LEN:415 FEET <br /> 3.OIN DIA LEN: 0 FEET L 8:DISP 7-8 <br /> TANK TEST NOTIFY: OFF 0.20 GPH TEST: MANUAL TRI-STATE (SINGLE FLOAT) <br /> TW TST SIPHON BREAKOFF 0.10 GPH TEST: AUTO CATEGORY : DISPENSER PAN <br /> SHUTDOWN RATE: 3.0 GPH <br /> LOW PRESSURE SHUTOFF:YES <br /> DELIVERY DELAY 5 MIN LOW PRESSURE : 10 PSI <br /> L 9:DISP 9-10 <br /> T 2:REGULAR TRI-STATE (SINGLE FLOAT) <br /> DISPENSE MODE: CATEGORY : DISPENSER PAN <br /> STANDARD <br /> SENSOR: HIGH PRESSURE <br /> PRESSURE OFFSET: O.OPSI <br /> LIO:DISP 11-12 <br /> TRI-STATE 0-31NGLE FLOAT) <br /> CATEGORY : DISPENSER PAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.