Laserfiche WebLink
Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Piot Plan available at http://vmw.swreb.ca.gov.) <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6,7,Health and Safety Code;Chapter 16,Division 3,77tle 23,California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CHEVRON 209167 Bldg.No.: <br /> Site Address: 1234 E.YOSEMITE AVE@ SPRECKLES City: MANTECA Zip: 95336 <br /> Facility Contact Person: MANAGER-KIM Contact Phone No.: 209-824-7433 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 2/12/2015 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: T:1-SUPREME Tank ID: T:2-REGULAR <br /> In-Tank Gauging Probe. Model: MAG 8473 17,;In-Tank Gauging Probe. Model: MAG 8463 <br /> R,Annular Space or Vault Sensor. Model: 794390909 r Annular Space or Vault Sensor. Model: 794390909 <br /> R Piping Sump/Trench Sensor(s). Model: 794380-208 P Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> r Fill Sump Sensor(s). Model: r Fill Sump Sensor(s). Model: <br /> j Mechanical Line Leak Detector. Model: (Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Veeder Root PLLD Electronic Line Leak Detector. Model: Veeder Root PLLD <br /> Tank Overfill/High-Level Sensor.Model: FLAPPER ./j Tank Overfill/High-Level Sensor.Model: FLAPPER <br /> Other(specify equipment a and model in Section E on Pae 2). Other(sE)ecifv equipment a and model in Section E on Pae 2). <br /> Tank ID: Tank ID: <br /> I In-Tank Gauging Probe. Model: r <br /> 7 In Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: ri Annular Space or Vault Sensor. Model: <br /> n Piping Sump/Trench Sensor(s). Model: r] Piping Sump/Trench Sensor(s). Model: <br /> r Fill Sump Sensor(s). Model: r Fill Sump Sensor(s). Model: <br /> 17 Mechanical Line Leak Detector. Model: j Mechanical Line Leak Detector. Model: <br /> (j Electronic Line Leak Detector. Model: [j Electronic Line Leak Detector. Model: <br /> (_Tank Overfill/High Level Sensor.Model: Tank Overfill/High Level Sensor.Model: <br /> Other(specify equipment a and model in Section E on Page rl Other(specify equipment a and model in Section E on Page 2). <br /> Dispenser 1/2 Dispenser 3/4 <br /> ID: ID: <br /> P Dispenser Containment Sensor(s).Model: 794380-208 r Dispenser Containment Sensor(s).Model: 794380-208 <br /> Shear Valve(s). r Shear Valve(s). <br /> I Dispenser Containment Float(s)and Chain(s). [ 1 Dispenser Containment Floats)and Chain(s). <br /> Dispenser 5/6 Dispenser 7/8 <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: 794380-208 Dispenser Containment Sensor(s).Model: 794380-208 <br /> r Shear Valve(s). r Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). r <br /> 1 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 9/10 Dispenser 11/12 <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: 794380-208 r!_e,;Dispenser Containment Sensor(s).Model: 794380-208 <br /> Shear Valve(s). ry—Oi Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). I ri Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report;(check all that apply):rk_6 System set- <br /> up �Alarm history report ,1rj1� <br /> Technician Name(print): Gilbert Garcia Signature: r_ c -f1_ <br /> Certification No.: 842816 License.No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)800-4633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 2/12/2015 <br /> Monitoring System Certification Page 1 of 3 12/07 <br /> *0-- <br /> PIVED <br /> AR 13 2015 <br /> EENVIRONMENTAL <br />