Laserfiche WebLink
San Joaquin County MAR 2 3 2015 <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue,Stockton, California 96206-6232 <br /> Telephone. (209)468-3420 Fbx;(209)408,3433 Web:www.slgoy.oW.hd.:NV1R0NMENTA <br /> k Pad <br /> Addrew. Date: <br /> CHEVRON STATION Q9167 1234 E YOSEMITE AVE, MANTECA February 12,2015 <br /> 4"t <br /> 321 CCR=6(0)(I) AM releases In secondary piping do not flow to a collection sump OV OR 0006 <br /> 322 CCR 2$W(2) Una le*detector not Installed 0 V a R Q COS <br /> 323 CCR 26Wf)(2) Leek detector failed to detect a 3.0 gph leak at 10 psi a a aGOS <br /> 324 CCR 2635(b) No spill bucket installed or failled to provide a m to keep it empty a o oCOS <br /> 325 CCR 2635(b) $pHl container failed to contain a minimum capacity of five gallons OV OR Ocos <br /> r328 CCR 2635(b)(2) Overfill prevention sydem m5t praanrlt,was overridden,or failed to meet o"rfill requirements OV o o COS <br /> 2" <br /> 327 HSC 25283.5 Unburied below grade UST failed to meet exemption status o a u COS <br /> 2 <br /> 32 3 a <br /> 28 CCR 2717.1(8) Tempered with red tog o a o COS <br /> 329 CCR 2717.1(1) Dep"Ited petroleum into a red tagged UST 0V o R oCOS <br /> --- <br /> 330. HSC 25200(%2) Tampered with or disablod leak detection devices or alarms o V o R a 60—S <br /> 331 CCR 2631.1 UST system not cornpatible with the subsWce stored o V a oCOS <br /> —77 <br /> 332 HSC 26M(b) Failed to comply with temporary closure requirements o V o R aCOS <br /> HSC 25298(c) Failed to comply with permanent closure requirements o V o R o COS <br /> io <br /> 401 26336(s)(3) <br /> —Fsuction piping not property etc or incorrectly located check valve aV a R o COS <br /> CCR <br /> 402 CCR 2643(d) Daily monlitaring of suction pipe(pre-Jan 1984)not performed c3 V a R a COS <br /> 403 CCR 260(d) Triennial 0.1 gph line test for conventional suction piping not pe&mwd(pre-JanuaFy 11984) OV on ocos <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not perfomiet!(pre-Jenuary 1984) a V o aCOS <br /> V <br /> 20110 See below UnlLsted Adrnlinis"tion/Documentation vilolaffon o o aCOS <br /> 2030 See below Unlisted Operatiorafflaintenanoe violation c3V o a000 <br /> 2060 See be Unlisted DeaWn/Consiructlon violation a a R a COS <br /> W,Y <br /> Ti4t <br /> Itern 8 <br /> 109 CCR 2637 Failed to test secondary containment. <br /> The post insWilation testing for the new sump penetrations(87 and 91-octane STP sumps)was conducted on <br /> January 31,2014(5R0068278)and the six month testing was due by July 2014. It appears that this testing has not <br /> been completed and is approximately six months past due. Secondary containment testing is required six months <br /> after installation and at least every 36 months after. Immediately schedule this test and provide the 48-hours <br /> notification to the EHO. Thlu Is a Class 11 violation. <br /> (11rdfial): Inspector Phonw. Vam: <br /> ELENA MANZO, REHS (209)953-7699 02t12/2015 <br /> —7 <br /> Page 3 of 4 <br />