My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1234
>
2300 - Underground Storage Tank Program
>
PR0516248
>
COMPLIANCE INFO_2015-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2023 11:28:32 AM
Creation date
6/3/2020 10:00:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2018
RECORD_ID
PR0516248
PE
2361
FACILITY_ID
FA0012532
FACILITY_NAME
CHEVRON STATION #209167
STREET_NUMBER
1234
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120016
CURRENT_STATUS
01
SITE_LOCATION
1234 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516248_1234 E YOSEMITE_2015-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O A n U I NEnvironmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON STATION#209167 1234 E YOSEMITE AVE,MANTECA February 01,2018 <br /> On Site Records <br /> 202 CCR 2712(b) Fated to maintain cathodic protection test records on site for at least 6 112 years n V n R ❑COS <br /> 203 CCR 2712(b) Failure to maintain records of repairs,lining,and upgrades on site,for the life of the UST a V o R o COS <br /> 204 CCR 2712(t) Current monitoring plan approved by the EHD not found on site o V a R o COS <br /> 205 CCR 2712(i),2634(e) Failure to submit a current UST Response Plan and have it available onsite o V o R u COS <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions ■V n R ❑COS <br /> 207 HSC 25294 Failed to record unauthorized release from primary containment a V a R o COS <br /> 208 CCR 2650(e),2652 Fated to notify the EHD of a reportable unauthorized release a V a R a COS <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed o V a R o COS <br /> 210 CCR 2715(e) Designated operator monthly inspection reports not maintained an site for at least 12 months a V o R a COS <br /> 211 CCR 2715(@(2) Designated operator employee training not performed or log not kept a V o R o COS <br /> 212 CCR 2715(f)(2) Unstaffed faa7tty failed to have or Implement a training program approved by the EHD o V o R o COS <br /> 213 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least dally or log not kept ❑V ❑R n COS <br /> 214 HSC 25281.5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept c V o R o COS <br /> 215 CCR 27120 Failure to retain a copy of the permit to operate at the facility ❑V a R o COS <br /> UST System Observations <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release,Including spits and overfills ❑V a R a COS <br /> 302 HSC 25291(b) UST system Incapable of detecting leak from primary into secondary containment(pre-Jul 2003) o V a R o COS <br /> 303 HSC 25290.2(d) Monitoring system not maintained to detect entry into secondary containment(Jul 2003-Jun 2004) o V o R a COS <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004) a V ❑R a COS <br /> 305 HSC 25290.1(a) VPH monitoring of the interstitial spaces of the UST system is not maintained o V o R o COS <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity a V a R a COS <br /> 307 CCR 2631(8),2632(c) Monitoring system of the Interstitial space of a double walled system not maintained ■V ■R a COS <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm o V o R a COS <br /> 309 CCR 2636(f)(1) Monitoring in sump!UDC fated to activate an audible and visual alarm or stop the Now product o V o R o COS <br /> 310 CCR 2636(f)(5) Failure to meet monitoring requirements in lieu of annual ilne tightness test o V o R a COS <br /> 311 CCR 2638(a),2641 Q) Failed to properly program or operate leak detection equipment o V o R o COS <br /> 312 CCR 2638((),2641(} Failed to affix a tag sticker on monitoring equipment certified,repaired,or replaced o V o R o COS <br /> 313 HSC 25290.1,25290.2, Failure to construct,operate,and maintain primary containment as product-tight a V o R o COS <br /> 25291 <br /> 314 HSC 25290.1,25290.2, Failed to have secondary containment or secondary containment not fight o V o R o COS <br /> 25291 <br /> 315 HSC 25291(e) Water in secondary containment not removed,analyzed,and properly disposed of(pre-Jul 2003) o V a R a COS <br /> 316 HSC 25290.1(c3), Secondary containment not constructed to prevent water intrusion(after Jul 2003) a V a R o COS <br /> 25290.2(c3) <br /> 317 CCR 2636(f)(2) Line leak detector not Installed a V o R o COS <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 g oh leak at 10 psi o V o R a COS <br /> FA0012532 PROSIS248 SC001 02/012018 <br /> EHD 23-01 Rev,101312017 Page 2 of 4 Underground Storage Tank Program OIR <br /> 1868 E.Hazelton Avenue I Stockton,California 952051 T 209 468-34201 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.