My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3304
>
2300 - Underground Storage Tank Program
>
PR0516354
>
COMPLIANCE INFO_2002-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 11:44:26 AM
Creation date
6/3/2020 10:00:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2007
RECORD_ID
PR0516354
PE
2361
FACILITY_ID
FA0012437
FACILITY_NAME
CHEVRON 352324
STREET_NUMBER
3304
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
07120013
CURRENT_STATUS
01
SITE_LOCATION
3304 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516354_3304 W HAMMER_2002-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mau, 19 05 11 : 01a Rff rda-Test (209) 794-0112 p. 4 <br /> } <br /> 1). Results of Testing/Servicing <br /> Software Version Installcd: _ __-•• .._.___. <br /> (:omplete the following checklist: <br /> Yes ❑ No* is the audible alarm operational? <br /> s ❑ Now Is the visual alarm operational'! <br /> Yc Q No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> es ❑ No* Were all setzars installed at lowest point of secondary containment and positioned so that other equipment <br /> not interfere with their proper operation? <br /> O Yes U N * if alarms are relayed to a remote monitoring station, is all communications equipment (e.g. mode <br /> /A operational? <br /> UPSes ❑ No* For pressuri7ed piping systems, does the turbine automatically shut down if the piping secondary containm <br /> ❑ N/A monitoring system detects a leak, fails to operate,or�s electrically disconnected? If yes:which sensors initi <br /> positive shut-down? (Check all that apply) ump/Trench Sensors; 0 Dispenser Contaiwnent Sensors. <br /> Did you confirm positivo shut-down due to leaks and sensor failure/disconnection? E des;❑No. <br /> O Yes G No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. <br /> mechanical overfill prevention.valve is installed),is the overfill warning alarm visible and audible at the to <br /> fill point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? �. <br /> ❑ Yes* o Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replac <br /> -and list the manufacturer name and model for all replacement parts in Section E,below. <br /> C1 Xes* o Was liquid found inside any secondary containment systems designed as dry systems? (Check all Thad app. <br /> d Product; d Water. If yes,describe causes in Section E,below. <br /> Li No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> Xes U No* Is all monitories equipment operational per manufacturer's specifications? <br /> a In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Commeiab- <br />