Laserfiche WebLink
1 <br />' 10 Label vial, using indelible ink, as follows <br /> A Sample I D No <br />' B Job I D No <br /> C Date and Time <br /> D Type of analysis required <br /> E Your name <br /> 11 Unless the fabric-type label is used, place Scotch'" tape over the label to preserve its <br />' integrity <br /> 12 For chain-of-custody reasons, sample vial should be wrapped end-for-end with Scotch'" <br /> tape or evidence tape and signed with indelible ink where the end of the tape seals on itself <br />' The septum needs to be covered <br /> 13 Chill samples Immediately Samples to be stored should be kept at 4° Celsius (C) (300 <br />' Fahrenheit [F]) Samples recenred at the laboratory above 10°C (as measured at glass <br /> surface by a thermocouple probe), after overnight shipping, will be considered substandard, <br /> so use a high quality cooler with sufficient ice or freezer packs <br /> 14 Fill out Chain-of-Custody Manifest and Analysis Request Form (see Chain of Custody <br /> Procedures, SOP 11) <br /> I <br /> 1 <br /> SOP 10 Page 2 of 2 <br /> ' JC®li <br /> GROUNDWATER <br /> U-11 TECHNOLOGY, INC <br /> I <br />