Laserfiche WebLink
' QuikStopnarkets, Inc. Page A-1 <br /> ectN7120 32 <br /> APPENDIX A <br /> SITE BACKGROUND <br /> Quik Stop Markets No. 120 <br /> 9321 North Thornton Road <br /> Stockton, California <br />' Quik Stop Market No. 120 currently utilizes four underground fuel storage tanks on-site: two <br /> 10,000-gallon gasoline tanks,one containing regular leaded gasoline and one containing unleaded <br />' gasoline, and two 8,000-gallon tanks, one containing diesel and the other premium unleaded <br /> gasoline In 1987, RESNA Industries Inc. (RESNA), operating under our previous name, <br /> Exceltech, Inc (Exceltech), installed a vadose monitoring system around the four tanks at the site, <br /> which detected the presence of hydrocarbons Leaks were found in the fuel system and were <br /> determined to be confined to the diesel fuel product lines The lines were then excavated and <br />' repaired Exceltech removed the contaminated soil and backfill material. Examination of the <br /> remaining soil and backfill indicated that the contamination had been removed The excavation was <br /> backfilled, the system precision tested,passed the test, and put back into operation <br /> In October 1990, RESNA completed a soil and groundwater investigation for the subject Quilt <br /> Stop Market in Stockton, California This investigation has began as an emergency response when <br /> in March 1990, the alarm of the leak detection system sounded. The investigation included drilling <br /> three exploratory borings, collecting soil samples at 5-foot depth intervals for identification and <br /> analysis, converting the borings to groundwater monitoring wells and collecting groundwater <br /> samples for laboratory analysts During the course of a leak detection test, not conducted by <br /> Exceltech, it was found that product lines were leaking. The product Imes were repaired, <br /> contaminated soil excavated and removed, and the excavation backfilled with clean fill (Exceltech, <br /> October 9, 1990) The system was then precision tested, passed the test, and put back into <br /> operation. In December 1990, a quarterly groundwater monitoring program was initiated <br />' In April 1991, due to regulatory concerns about hydrocarbons found in groundwater during the <br /> December 1990 sampling and analysis, an additional sampling and analysis was performed This <br /> sampling and analysis confirmed the non-detectable results of the March 1991 sampling and <br />' analysis In February 1992, after four consecutive quarters of non-detectable results, Quik Stop <br /> Markets requested reduction of quarterly sampling and analysis to a semiannual schedule On <br /> March 3, 1992,the San Joaquin County Public Health Services approved this request <br /> Reference <br /> Exceltech, Inc , October 1990, "Soil and Groundwater Investigation, Quilt Stop No 120, <br /> Stockton, California, Project No. 3-49120-31," unpublished report for Quik Stop Market, <br /> Inc , Fremont, California <br /> r <br />