Laserfiche WebLink
The following is an itemized list of hazardous waste violations that have not been <br /> addressed for Grayson Engineering (Lodi CA) as of June 12, 2020. <br /> Open violations from November 26, 2019 inspection <br /> Violation #102 -Failed to determine if a waste is a hazardous waste. <br /> OBSERVATIONS One 55 gallon drum containing oily cardboard, oily rag, oily container, and an aerosol was stored <br /> outside the storage shed without a lid or determination being made. One lead acid battery was observed on top of a <br /> five gallon container with no determination being made. <br /> REGULATION GUIDANCE: Any person who generates a waste shall determine if the waste is a hazardous waste <br /> as specified in Title 22 California Code of Regulations (CCR). There are wastes that are listed as hazardous <br /> wastes. There are wastes that exhibit one or more of the hazardous waste characteristics: toxic, corrosive, reactive <br /> or ignitable. <br /> CORRECTIVE ACTION: Immediately make a hazardous waste determination for each waste , and manage it <br /> according to Title 22 CCR. Use Safety Data Sheets (SDS), waste sampling and test results or other knowledge to <br /> support your hazardous waste determination. Waste testing must be done using methods specified in Title 22 CCR <br /> including sections 66261.20-24. <br /> Submit a statement and supporting documentation with your hazardous waste determination. Demonstrate current <br /> storage and labeling for wastes determined to be hazardous wastes. Provide disposal records for wastes <br /> determined to be hazardous wastes and stored longer than the number of days specified in Title 22 CCR for your <br /> hazardous waste generator status. <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Page 1 of 1 <br />