Laserfiche WebLink
S A N J O A Q I I I N Environmental Health Department <br /> COUNTY— AMENDED <br /> 3/17/2020 <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PROFLEET TRUCK LUBE (LUBEZONE INC) 24511 N HWY 99 , ACAMPO December 23, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> operated so that it will detect either the failure of the primary and secondary containment structure or any release of <br /> hazardous waste or accumulated liquid in the secondary containment system within 24 hours, or at the earliest <br /> practicable time if the existing detection technology or site conditions will not allow detection of a release within 24 <br /> hours. <br /> Title 22 California Code of Regulations section 66265.193(f) <br /> (f)Ancillary equipment shall be provided with full secondary containment(e.g., trench,jacketing, double-walled <br /> piping)that meets the requirements of subsections(b)and (c)of this section except for: <br /> (1)aboveground piping (exclusive of flanges,joints, valves, and connections)that are visually inspected for leaks on <br /> a daily basis; <br /> (2)welded flanges,welded joints, and welded connections that are visually inspected for leaks on a daily basis; <br /> (3)sealless or magnetic coupling pumps and sealless valves,that are visually inspected for leaks on a daily basis; <br /> and <br /> (4)pressurized aboveground piping systems with automatic shut-off devices(e.g., excess flow check valves,flow <br /> metering shutdown devices, loss of pressure actuated shut-off devices)that are visually inspected for leaks on a <br /> daily basis. <br /> CORRECTIVE ACTION: Have a qualified Professional Engineer update the tank assessment and add the missing <br /> sections. Provide a corrective action statement and supporting documentation to the San Joaquin County <br /> Environmental Health Department(EHD)within 30 days. Provide a copy of the updated assessment,when <br /> available. <br /> This is a Class II violation. <br /> 605 CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste. <br /> OBSERVATION: Hazardous waste containers were observed on-site with incomplete labeling. The containers <br /> were: <br /> -One red five gallon container that collects oil from the P200L oil filter crusher was observed without hazardous <br /> waste label. <br /> REGULATION GUIDANCE: All hazardous waste containers shall be marked with the following information: the <br /> words"Hazardous Waste", name and address of generator, hazardous properties, physical state, composition <br /> (contents), accumulation start date <br /> CORRECTIVE ACTION: Immediately label the container as required for hazardous waste. Provide a corrective <br /> action statement and supporting documentation to the San Joaquin County Environmental Health Department <br /> (EHD)within 30 days. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator on the day of inspection. The EHD has written the <br /> complete report on January 3, 2020 which replaces the initial checklist. <br /> FA0025324 PR0544547 SCO01 12/23/2019 <br /> EHD 22-02 Rev.9/20/2019 Page 12 of 13 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />