My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0007568
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3425
>
3500 - Local Oversight Program
>
PR0545737
>
ARCHIVED REPORTS_XR0007568
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/8/2020 11:42:19 AM
Creation date
6/8/2020 9:55:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0007568
RECORD_ID
PR0545737
PE
3528
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
02
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ATTACHMENT A <br /> REMEDIAL SYSTEM PERFORMANCE EVALUATION <br /> The SVE/AS systems were initiated on January 4, 1996 and June 18, 1997, respectively A brief description and <br /> performance evaluation of the remedial system during First Quarter, 2002 are presented below Certified <br /> laboratory analytical reports,chain-of-custody documentation,and field data sheets are included as Attachment A-A <br /> SVE System <br /> The SVE system is comprised of 11 SVE wells (VES-1 through VES-7, and ATR-3, ATR-4, ATR-5, and TEX-1) <br /> and a King Buck Hasstech 100-cfm catalytic oxidizer The SVE system is permitted by the San Joaquin County <br /> Unified Air Pollution Control District (SJCUAPCD) Permit to Operate Number N-3413-1-0, for operation through <br /> December 31,2005 <br /> The system remained off due to low influent concentrations To date, the SVE system has removed approximately <br /> 3,616 6 pounds of TPHg and 10 6 pounds of benzene from the soil and groundwater beneath the site Histoncal <br /> . SVE system performance and analytical data are summarized in Tables A-1 through A-3 Graphical presentations of <br /> TPHg mass removal and influent concentration data are shown on Figures A-i and A-2 <br /> AS System <br /> The AS system is comprised of 11 AS wells (VES-1 through VES-7, S-1 through S-3, and SMW-1) and a Conde <br /> 7 5-hp sparge blower The AS system operated at an average infection pressure of 4 6 psi and an average flow rate <br /> of 62 cfm AS system operational data, including well open/closed status, flow rate and applied pressure, are <br /> presented in Table A-4 Historical dissolved oxygen levels for site wells are presented in Table 1 of this report <br /> Conclusion <br /> The AS system will continue to be operated during the second quarter 2002, the SVE system will be pulsed, and <br /> then evaluated to determine if it will be operational <br /> Attachments Table A-1 - Soil Vapor Extraction System Performance Data <br /> Table A-2 - Soil Vapor Extraction System Emission Data <br /> Table A-3 - Soil Vapor Extraction System Well Data <br /> Table A-4 - Air Sparging System Well Data <br /> Figure A-1- Soil Vapor Extraction System Mass Removal Trend <br /> Figure A-2- Soil Vapor Extraction System Hydrocarbon Concentrations <br /> Attachment A-A—Remedial System Field Data Sheets <br /> • <br />
The URL can be used to link to this page
Your browser does not support the video tag.