ARCHIVED REPORTS_XR0008009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3425
>
3500 - Local Oversight Program
>
PR0545737
>
ARCHIVED REPORTS_XR0008009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/8/2020 11:25:22 AM
Creation date
6/8/2020 10:12:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0008009
RECORD_ID
PR0545737
PE
3528
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
02
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ATTACHMENT A <br /> REMEDIAL SYSTEM PERFORMANCE EVALUATION <br /> Soil vapor extraction (SVE) and air sparging were initiated on January 4, 1996 and June 18, 1997, <br /> respectively A brief description and performance evaluation of the remedial system between October 5, 1999 <br /> and December 15, 1999 are presented below <br /> SVE System <br /> The SVE system is comprised of 11 SVE wells (VES-1 through VES-7, and ATR-3, ATR-4, ATR-5, and <br /> TEX-1) and a King Buck Hasstech 100 cfm catalytic oxidizer The SVE system is pernutted by the San <br /> Joaquin County Unified Air Pollution Control District (SJVUAPCD) Permit to Operate Number N-3413-1-0, <br /> for operation through January 1, 2002 <br /> The SVE system was approximately 86% operational ttus quarter During thus period, the SVE system <br /> removed approximately 54 2 pounds of TPH-g To date, the SVE system has removed approximately 3,484 <br /> pounds of TPH-g from the soil and groundwater beneath the site Due to relatively low influent concentrations <br /> the SVE/AS will be pulsed during the first quarter of 2000 Historical SVE system performance and analytical <br /> data are summarized in Tables A-1 and A-2 Graphical presentations of TPH-g mass removal and influent <br /> ooncentrahon data are shown on Figures A-1 and A-2 <br /> Air Sparging System <br /> The air sparge system is comprised of 11 air sparge wells(VES-1 through VES-7, S-1 through S-3, and SMW- <br /> 1)and a Conde 7 5-horsepower sparge blower <br /> The air sparging system operated at an average injection pressure of 7 0 psi and an average flow rate of 15 8 <br /> cfm The air sparge system was approximately 86%operational flus quarter Air sparging system operational <br /> data,including well open/closed status,flow rate and applied pressure, data are presented in Table A-3 <br /> Dissolved oxygen levels for site wells is presented in Table A-4 <br /> Attachments Table A-1 - Soil Vapor Extraction System Performance Data <br /> Table A-2 - Soil Vapor Extraction Emission Data <br /> Table A-3 - Soil Vapor Extraction System Well Data <br /> Table A-4 - Air Sparging System Well Data <br /> Table A-5 - Dissolved Oxygen Well Concentrations <br /> Figure A-1 - Soil Vapor Extraction System Removal Trend <br /> Figure A-2 - Soil Vapor Extraction System Hydrocarbon Concentrations <br /> Attachment A-A - Certified Analytical Reports,Chain of Custody Documentation,and <br /> Remedial System Field Data Sheets, <br />