Laserfiche WebLink
• • • <br /> Lancaster Laboratories <br /> s Where quality is a science <br /> Page 1 of 2 <br /> Lancaster Laboratories Sample No. WW 3715004 <br /> Collected 10/24/2001 17 30 by FT Account Number 10906 <br /> i <br /> Submitted 10/26/2001 09 20 Chevron Products Company <br /> Reporzed 11/30/2001 at 1737 - -6001 Bollinger Caftyon Rd <br /> Discard 12/31/2001 T Building L PO Box 6004 <br /> MW-4-W-011024 Grab Water San Ramon CA 94583-0904 <br /> - -Facility# 9-8264-- Job# 386854 -- - —GRD --~ - - - - - - <br /> 3775 Tracy Blvd Tracy T0607700627 MW-4 <br /> 4W241 <br /> As Received <br /> CAT As Received Method Dilution <br /> No. Analysis Name CAB Number Result Detection Units Factor <br /> Limit <br /> 05553 TPH - DRO CA LUFT (waters) n a 3,100 390 ug/l 20 <br /> According to the California LUFT Protocol, the quantitation for Diesel <br /> Range Organics was performed by peak area comparison of the sample pattern <br /> to that of our #2 fuel oil reference standard (between C10 and C28 normal <br /> hydrocarbons) <br /> Site-specific MS/MSD samples were not submitted for the project A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level <br /> A dilution was required to bring target compounds into the calibration <br /> range of the system The reporting limits are raised accordingly <br /> 01729 TPH-GRO N California (waters) <br /> 01730 TPH-GRO N California (waters) n a 15,000 250 ug/i 5 <br /> The reported concentration-of-TPH-GRO does not include MTBE-or other -- - - - - <br /> gasoline constituents eluting prior to the C6 (n-hexane) TPH-GRO range <br /> start time <br /> Site-specific-MS/MSD-samples-were-not-submitted-far-the-project -A-LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level <br /> 08214 BTEX, MTBE (8021) <br /> 00776 Benzene 71-43-2 N D # 20 ug/l 5 <br /> 00777 Toluene 108-88-3 430 1 0 ug/l 5 <br /> 00778 Ethylbenzene 100-41-4 350 1 0 ug/1 5 <br /> 00779 Total Xylenes 1330-20-7 1 700 3 0 ug/1 5 <br /> 00780 Methyl tert-Butyl Ether 1634-04-4 590 2 S ug/l 5 <br /> Site-specific MS/MSD samples were not submitted for the project A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level <br /> Due to the presence of an interferent near its retention time, the normal <br /> reporting limit was not attained for benzene The <br /> presence or concentration of this compound cannot be determined due to the <br /> presence of this interferent <br /> Lancaster Laboratories Inc <br /> M E M B E R 2425 New Holland Pike <br /> PO Box 12425 <br /> Lancaster PA 17605 2425 <br /> 717-656 2300 Fax 717-656 2681 2216 Rev 9111100 <br />