h'9 KLEINFELDER <br /> was analyzed for the first time in January 2001, was detected in the groundwater sample collected <br /> from MW-1 at 3 3 mg/l <br /> Based upon analytical data obtained during these sampling events, the CVRWQCB and EHD <br /> requested continued quarterly groundwater sampling and preparation of a workplan to address the <br /> extent of the contamination in the vicinity of the subject site, Including a sensitive receptor survey <br /> and estimates as to the amount of contamination in soil and groundwater <br /> At the request of General Mills, Klemfelder installed three additional monitoring wells in the <br /> vicinity of the UST in January 2002 (MW2, MW-3 and MW4) During the Installation, soil <br /> samples were collected from the bonngs and submitted for laboratory analysis None of these <br /> samples contained detectable concentrations of TPH-G, TPH-D, nor BTEX, at or above laboratory <br /> reporting limits <br /> Four quarterly sampling events were conducted in 2002 with groundwater samples collected from <br /> all four monitoring wells MW-1 through MW-4 Monitoring wells MW-2, MW-3 and MW-4 were <br /> installed as perimeter monitoring wells MW-2 and MW-3 were Installed downgradient of the UST <br /> area and MW-1 was installed upgradient of the UST area Based on findings of the four quarterly <br /> sampling events conducted during 2002, fuel constituents continued to be present in MW-1, <br /> including TPH-D, TPH-G, ethylbenzene and total xylenes at relatively lower concentrations (See <br /> Table 2) Floating product was noted in September 2002 in monitoring well MW-1 Product <br /> thickness since this time has been noted in MW-1 at thicknesses ranging from a film (<0 01 feet) to <br /> approximately 4 inches A trace concentration of TPH-D (0 076 mg/1) was detected in the June <br /> 2002 sampling event in downgradient well MW-2 No petroleum constituents were otherwise <br /> detected in perimeter monitoring wells MWs 2, 3 or 4 in 2002 <br /> During the quarterly sampling events in 2003 petroleum constituents were detected only in MW-1, <br /> with the exception of the 3rd Quarter, 2003 in which TPH-D was detected in MW-2 at 0 14 mg/l <br /> Product was measured in MW-1 in consecutive quarterly events in 2003, beginning with the I" <br /> quarter 2003 at 4, 1/2, 3/4 and 114 inches, respectively TPH-D ranged from 13 to 32 mg/l in MW- <br /> 1 during 2003 Product thickness measured in MW-1 during 2004 ranged from 1/2 inch (I" <br /> quarter) to 1/5 inch (3`d quarter) In 2004, TPH-D concentrations ranged from 500 mg/l (151 quarter) <br /> to 24 mg/l (3rd quarter) No requested petroleum constituents were detected in MWs 2, 3 or 4 <br /> during the 2004 quarterly sampling events <br /> The following Sections document Kleinfelder's findings from the first quarter 2005 sampling event <br /> 28201 T06/ST05R717/LTV iv Page 5 of l l <br /> ©2005, Klemfelder, Inc June 23,2005 <br />