Laserfiche WebLink
Quarterly Report - Second Quarter 2003 <br /> • PLAZA LIQUORS II <br /> 2420 West Turner Road, Lodi, California <br /> 1.0. INTRODUCTION <br /> I At the request of Mr Robert McCarty,Advanced GeoEnvironmental, Inc (AGE)has prepared this <br /> quarterly report for the property located at 2420 West Turner Road, Lodi, California The scope of <br /> work included performance of a quarterly ground water monitoring event and preparation of this <br /> report The site and the surrounding area are illustrated in Figure 1 On-site structures and monitoring <br /> well locations are illustrated on Figure 2 Site Background information is summarized in <br /> Appendix A <br /> 2.0. PROCEDURES <br /> IFieldwork was performed in accordance with guidelines established by the Central Valley Regional <br /> Water Quality Control Board(CVRWQCB)for the investigation ofunderground storage tank(UST) <br /> sites <br /> i2 1 WELL MONITORING AND PURGING <br /> On 07 April 2003, the depth to ground water in all eight monitoring wells was measured from the <br /> Itop of each well casing to the nearest 0 01-foot utilizing a Solmst water level meter Ground water <br /> elevation in each well was calculated by subtracting the measured depth to ground water from the <br /> surveyed casing elevation (Table 1) <br /> After recording water level measurements, dedicated disposable plastic bailers were used to purge <br /> the wells of standing water Approximately 6 0 to 8 0 gallons of water(a minimum of 3 casing-water <br /> volumes per well) were removed from wells MW1 through MW8 Ground water temperature, pH <br /> and conductivity were measured at regular intervals during purging using an Oakton water analyzer <br /> Field sheets and data are included in Appendix B Purged water was stored in properly labeled DOT- <br /> approved model 17H 55-gallon drums and stored on-site <br /> E22 COLLECTION AND ANALYSIS OF GROUND WATER SAMPLES <br /> Water samples were collected from each purged well using new disposable plastic bailers after <br /> allowing the wells to achieve a minimum 80%recovery of the pre-purge water volume Each water <br /> sample was transferred into one I-liter amber bottle without sample preservative and into three <br /> 40-m1 VOA vials containing 0 5 ml 18% hydrochloric acid as a sample preservative After <br /> collection, the samples were properly labeled, placed in a chilled container and transported under <br /> IAdvanced GeoEnvi ron mental,Inc <br /> I <br />