My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0012641
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
4614
>
3500 - Local Oversight Program
>
PR0545770
>
ARCHIVED REPORTS_XR0012641
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/12/2020 10:59:14 PM
Creation date
6/9/2020 2:05:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0012641
RECORD_ID
PR0545770
PE
3528
FACILITY_ID
FA0006278
FACILITY_NAME
WOODBRIDGE VINEYARD ASSOC
STREET_NUMBER
4614
Direction
W
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95240
CURRENT_STATUS
02
SITE_LOCATION
4614 W TURNER RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
470
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SEBASTIANI VINEYARDS/ <br /> VOODBRIDGE CELLARS <br /> SITE ASSESSMENT <br /> LODI, CALIFORNIA <br /> yEXECUTIVE SUMMARY <br /> This site assessment report has been prepared as a result of fuel <br /> hydrocarbon contamination cf soils and groundwater associated with a <br /> former underground fuel storage tank located at the Sebastiani Vineyards/ f <br /> .., Woodbridge Cellars facility in Lodi, California. <br /> Prior to McLaren Engineering, involvement in this project, the tank was � <br /> removed and fuel was observed directly beneath the former location of the <br /> tank. A subsequent excavation of soils down to the groundwater table was <br /> monitored by McLaren Engineering and, based on the occurrence of petroleum <br /> hydrocarbons in soils and groundwater from the excavation pit, a <br /> comprehensive site assessment operation was initiated. The site <br /> assessment included soil sampling, monitor well construction and <br /> groundwater sampling from five soil borings, two soil aeration areas, ten <br /> groundwater monitoring wells, and two site supply wells. Results of the <br /> site assessment indicate that soil contamination extends laterally from <br /> the excavation pit between 15 and 35 feet. Soil contamination begins at <br /> a depth of 7 to 12 feet below ground surface and extends to the shallow <br /> groundwater table at 18 feet below ground surface. Contamination of the <br /> shallow grounde:ater unit at this site extends laterally from the <br /> excavation pit to the southwest a maximum 100 feet. Vertical <br /> contamination of groundwater is contained within the shallow groundwater <br /> : 1 unit which is underlain by a silty clay unit with a minimum thickness of <br /> 5 feet. <br /> Site assessment findings indicate that remediation of soils and <br /> _0 groundwater are required. Specific elements of remediation and <br /> implementation of those elements will be presented in the McLaren <br /> Engineering, Final Remedial Plan. <br /> INTRODUCTION <br /> This report presents results of McLaren Engineering's soil and groundwater <br /> investigation at the Sebastiani Vineyardslrloodbridge Cellars facility at <br /> 4614 West Turner Road in Lodi, California. The location of the project <br /> '-. site is shown in Figure 1. The investigation was conducted in accordance <br /> with the work plan submitted to Sebastiani Vineyards and the San Joaquin <br /> Local Health District (SJI11D) on April 12, 1989, and the April 20 and May <br /> W 1, 1989, work plan addendums. The work plan presented a program to <br /> characterize the extent of soil and groundwater contamination associated <br /> with-a former u-nrground-fuel_storage-tank--at-the-site,--In-general-the <br /> - - -- <br /> - ------------ -- ----------- ----de- <br /> T site assessment work included; 1) completing soil borings and groundwater <br /> monitoring wells; 2) laboratory analysis of soil and groundwater samples; <br /> and 3) preparation of a site assessment report for subrdittal to regulatory <br /> agencies. <br /> 1 - <br />
The URL can be used to link to this page
Your browser does not support the video tag.