Laserfiche WebLink
RESULTS OF CERTIFIED ANALYSIS OF GROUNDWATER SAMPLES <br /> The results of the certified analyses ofg samples roundwater les collected from the three <br /> monitor wells on December 2, 1999 are shown in Table 1 Copies of the laboratory <br /> reports are included as Appendix C of this report <br /> TPH-G concentrations ranged from a maximum of 21000 ug/l at monitor well MW 1 to <br /> 4500 ug/l at monitor well MW2 <br /> Benzene concentrations ranged from a maximum of 6600 ug/1 at MW I to 550 ug/l at <br /> MW2 <br /> MTBE concentrations ranged from a maximum of 70 ug/1 at MW3 to 20 ug/1 at MW2 <br /> Figure 5 shows the distribution of TPH-G BTEX, and MTBE in groundwater and the <br /> estimated lateral limits of the TPH-G in groundwater as detennined from groundwater <br /> samples collected on December 2, 1999 The decrease in overall groundwater elevation <br /> since the previous quarterly monitoring round was not accompanied by any significant <br /> changes in TPH-G, BTEX, or MTBE concentrations at any of the three monitor wells <br /> RECOMMENDATIONS <br /> 1) Continue quarterly groundwater monitoring <br /> 2) Implement September 28, 1999 workplan to install additional groundwater monitoring <br /> wells following approval by SJCEHD <br /> LIMITATIONS <br /> The discussion presented in this report is based on the following <br /> 1 The observations and data collected by field personnel <br /> 2 The results of laboratory analyses performed by a state certified analytical laboratory <br /> 3 Our understanding of the regulations of San Joaquin County and the State of <br /> California <br /> Changes in groundwater conditions can occur due to variations in rainfall, temperature, <br /> local and regional water use, and local construction practices In addition, variations in <br /> the soil and groundwater conditions could exist beyond the points explored in this <br /> investigation <br /> State Certified Laboratory analytical results are included in this report This laboratory <br /> follows EPA and State of California approved procedures, however, WEGE is not <br /> responsible for errors in these laboratory results <br /> 3 Arc Pump QM 10-12 1999 <br />