My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1257
>
2300 - Underground Storage Tank Program
>
PR0231463
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/3/2020 1:10:21 PM
Creation date
6/10/2020 11:46:31 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231463
PE
2361
FACILITY_ID
FA0003707
FACILITY_NAME
AHMEDS SONS INC
STREET_NUMBER
1257
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
20015015
CURRENT_STATUS
01
SITE_LOCATION
1257 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, � � <br /> � l,l Environmental Health Department <br /> SAN JOAQUIN rrT <br /> CUU N 1 Y <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address : Date: <br /> AHMEDS SONS INC 1257 W YOSEMITE AVE , MANTECA April 10 , 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 307 CCR 2631 (g) , 2632(c) Monitoring system of the interstitial space of a double walled system not maintained . <br /> The 87 product annular sensor failed to activate an audible and visual alarm when tested and , therefore , the tank is <br /> not monitored . The interstitial space shall be monitored with a monitoring system connected to an audible and <br /> visual alarm system . Immediately contact a properly licensed , trained , and certified contractor to replace the failed <br /> component with a functional component ( LG 113-x listed , if applicable) under permit, if required , of the EHD within <br /> one business day. <br /> This is a repeat violation , Class II , <br /> 319 CCR 2635 , 2637 . 11 2665 , 2712 No spill bucket, failed to contain 5 gallons , no means to keep it empty, or failed to be <br /> tested . <br /> The 91 product spill container failed when tested . All spill containers shall have a minimum capacity of five gallons <br /> and be capable of containing a spill or overfill until it is detected or cleaned up . The spill container drain valve was <br /> replaced and retested during the inspection . <br /> This was corrected on site. <br /> This is a repeat violation , Class II , <br /> 320 CCR 2635 , 2637 . 2 , 2665 , 2712 Failure to comply with the installation , inspection , or record keeping of the overfill <br /> prevention . <br /> Owners or operators of underground storage tanks that do not meet California Code of regulations , title 23 division <br /> 3 , chapter 16 section 2635 (c) (2) shall test overfill prevention equipment once by October 13th , 2018 and every 36 <br /> months thereafter; and within 30 days of the date of a repair. The site conducted the test on 4/11 /19 , over five <br /> months late. Ensure to conduct overfill prevention equipment inspection within the time frame provided by the <br /> regulation and submit test results within 30 days of performing the inspection . Ensure a 48 hour notification is <br /> provided to EHD prior to conducting the inspection . Test result for the testing performed must be submitted within <br /> 30 day of testing . <br /> This is a Class II violation . <br /> Overall Inspection Comments : <br /> NOTE : Due to unavailability of San Joaquin County Environmental Health department inspectors , an inspector <br /> from the San Joaquin county environmental health department was not present during the entire monitoring <br /> system certification . The inspector was able to witness inside the under dispenser containment, the submersible <br /> turbine pump sumps , and spill containers of the UST system . EHD awaits the monitoring system certification <br /> results to review the functionality and communication of the monitoring system . Ensure the monitoring system <br /> certification is submitted to EHD within 30 days of the testing date . An inspection checklist was provided to the <br /> facility operator on the day of inspection . The EHD has written the complete report which replaces the initial <br /> checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> FA0003707 PR0231463 SCO01 04/10/2019 <br /> EHD 23-01 Rev. 09/28/2018 Page 7 of 8 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 F 209 464-0138 1 www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.