Laserfiche WebLink
3 ' <br /> 00AA0 OF TMUSfEES SAV JOAQUIN LOCAL.HEALTH DISTRICT sERvifao <br /> Jars*a crrit-oson,Pua. City of Lodi <br /> F <br /> r.rrr.,:'a E. Vannuccl, San Joaquin County <br /> Ante la Van Soronaan 1601 f=eat Haue1lon Avenue,P.O. Box 2009 <br /> of, nh1 City of Eacalnn <br /> Stockton.California 95201 City of f,fantece <br /> =arn�-up6sa <br /> )anl' t.flo,aa 209/466-6781 City of Ripon <br /> t� City of Stockton <br /> john u,M-41, M.O. City of Tracy <br /> V11114 t J.Wads Joal Khanna,M.O..M.P.H.,014trtct Health 011icw San Joaquin County <br /> ;arypna Lora San Joaquin County <br /> F c i 1 i ty Nc,,:e )YY-'L rt t r :tv\L <br /> adress (DQ� LlrlrtAl <br /> l to of Inspection Inspector �4�L� <br /> HITORYNG ALlERNATIYE d7 U <br /> Limited to undernroand storage tanks which have infrequent inputs and withdrawals and <br /> T`ere the Iigtfit: level in the tank can be measured to an accuracy of +5 gallons or less <br /> en the tank is half full. <br /> Tis monitoring alternative shall include: <br /> F`v-"Annual precision test on tank and piping. <br /> tank gauging performed as follows: <br /> W �ank frust be capable of being secured to prevent unauthorized inputs and <br /> withdrawals. <br /> ^ Tank frust have no inputs or withdrawals for at least a 48 hour period <br /> (2 days) at the end of consecutive periods lasting up to 1 days. <br /> (For example: tank in use Monday through Friday, then locked <br /> over weekend). <br /> L-�Liquid level measurements are taken at the beginning and end of the <br /> monitoring period (lasting at least 48 hours). <br /> (For example: level measured and recorded Friday night before <br /> flocking and again an Monday morning before opening. ) <br /> If liquid level varies more than 1% of the tank volume or 5 gallons, which <br /> ever is less, between Inca suren>ents, an unauthorized release shall be <br /> assumed to have occurred and shall be reported to the local agency within <br /> ?4 hours, as per Article 5. Sect. 2652 of the regulations and further <br /> evaluations shall be performed to verify or disprove the variations. <br /> co. eu,entation of the monitoring alternative requires that the following circled items be <br /> )Icted by the dates succi fieri. <br /> i. Precision test(s) must be performed by c.;)- and results submitter) to this <br /> office within 30 days of the tr ;t. <br /> tank gauging must be started imnediately. (See instructions above). <br /> If thu above [om Lienee dSics taiiiii�t-tie- con thtt [h r; office prior-to the sl}rci C41 <br /> .4/86 UGi 3 <br />