Laserfiche WebLink
Quarterly Report - First Quarter 2002 <br /> COMFORT AIR, INC. <br /> 1607 Turnpike Road, Stockton, California <br /> 1.0. INTRODUCTION <br /> At the request of Mr Greg Gaut, Advanced GeoEnvironmental, Inc (AGE) has prepared this <br /> quarterly report for Comfort Air,Inc , 1607 Turnpike Road,Stockton,California(site) The location <br /> of the site is illustrated in Figure 1, a plan of the site is illustrated in Figure 2 <br /> IThe objective of the work was to monitor dissolved petroleum hydrocarbon concentrations in ground <br /> water and to characterize ground water flow direction and gradient on the site This report is prepared <br /> in accordance with guidelines Issued by the Central Valley Regional Water Quality Control Board <br />' (CVRWQCB) for investigation of underground storage tank (UST) sites A summary of previous <br /> investigations at the site was included in the AGE-prepared Quarterly Report-February 1997,dated <br />' 18 April 1997, and Monitoring Well Installation Work Plan -July 1998, dated 23 July 1998 <br /> 2.0. PROCEDURES <br /> On 12 February 2002, ground water monitoring and sampling was performed at the site on wells <br /> • MW-1 through MW-8 Field activities were performed in accordance with guidelines for <br /> investigation of underground storage tank(UST)sites and sampling ground water monitoring wells <br /> issued by the Regional Water Quality Control Board-Central Valley Region(RWQCB) and by the <br /> San Joaquin County Environmental Health Department (EHD), respectively <br /> 2 1 WELL MONITORING AND EVACUATION <br /> A Solmst water level meter was used to measure the depth to ground water in the eight monitoring <br /> wells relative to the tops of the well casings, the ground water elevations and gradient were <br /> determined from these data(Table 1) After the depth-to-ground-water measurements, a minimum <br /> of 3 casing-water volumes of water was purged from each well using a PVC submersible two-stage <br /> pump or a new, clean, disposable plastic bailer Approximately six to twenty-two gallons of water <br /> were removed from wells MW-1 through MW-8 <br /> Temperature,pH and conductivity of purged ground water were measured at 1-to 4-gallon intervals <br /> using an Oakton water analyzer The field data and field sheets are included in Appendix A Purged <br /> water was temporarily stored on-site in 55-gallon DOT-approved H-17 storage drums pending proper <br /> disposal <br /> Following purging,the depth to ground water was measured to ensure that a minimum of 80%well- <br /> volume recharge had been achieved prior to sampling However, monitoring well MW-6, screened <br /> in a deeper zone, was sampled prior to reaching 80% recovery <br /> Advanced GeoEnvironmental,Inc <br />