' Quarterly Report - Fourth Quarter 2005 <br /> • COMFORT AIR, INC. <br />' 1607 Turnpike Road, Stockton, California <br />' I.0. INTRODUCTION <br /> At the request of Mr Greg Gaut, Advanced GeoEnvironmental, Inc (AGE) has prepared this <br />' quarterly report of environmental activities conducted at Comfort Air, Inc , 1607 Turnpike Road, <br /> Stockton, California (site) The scope of work included performance of a quarterly ground water <br /> monitoring event and preparation of this report The objective of the work was to characterize ground <br />' water flow direction and gradient on the site and monitor dissolved petroleum hydrocarbon and fuel <br /> additive concentrations from monitoring well samples The location of the site is illustrated in <br />' Figure 1 A plan of the site is illustrated in Figure 2 <br /> This report is prepared in accordance with guidelines issued by the Central Valley Regional Water <br />' Quality Control Board (CVRWQCB)for investigation of underground storage tank(UST) sites A <br /> summary of previous environmental assessment activities are included in Appendix A Historical <br /> ground water monitoring results are summarized on Tables 1 and 2 <br /> I <br /> 2.0. PROCEDURES <br /> • Field activities were performed in accordance with guidelines for investigation of underground <br /> storage tank(UST)sites and sampling groundwater monitoring wells issued by the CVRWQCB and <br /> by the San Joaquin County Environmental Health Department (EHD), respectively <br /> 2 1 QUARTERLY WELL MONITORING <br /> On 03 November 2005,a ground water monitoring event was conducted at the site A total of sixteen <br /> wells were monitored and sampled <br /> 2 1 1 Well Monitoring and Evacuation <br /> A Solinst water level meter was used to measure the depth to ground water in wells MW-3, MW-5, <br /> MW-6, MW-7, MW-8A/B through MW-12A/B (except for MW-1 IA), MW-13 and EX-1 relative <br /> to the tops of the well casings (Table 1) Well MW-I IA was inaccessible for purging or sampling <br /> due to a car parked directly over it However,depth to ground water was able to be measured After <br /> the depth-to-ground-water measurements were recorded for each well, a minimum of three casing- <br /> water volumes of water were purged from each well using Watera Hydro-Lift II pump for wells <br /> MW-3,MW-5,MW-7 and MW-8A through MW-I3 Approximately 4 5 to 14 gallons ofwater were <br /> removed from shallow-screened wells MW-3, MW-5, MW-7 and MW-8A through MW-12A, <br /> I approximately 21 to 27 gallons of water were removed from deep-screened wells MW-813,MW-1 OB, <br /> 1 <br /> Advanced GeoEnvironmental,Inc <br />