Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Pagel of 6) <br /> This form must be used to document testing and servicing of underground storage tank ( UST) monitoring equipment . A copy <br /> of this form must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local <br /> agency regulating the USTs within 30 days of the date of the monitoring system certification , <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10181511 7/29/19 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) Building <br /> KwikSery #98 <br /> Business Site Address City ZIP Code I <br /> 2501 Jackson Ave . Escalon 95320 <br /> P P1 I <br /> lit UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone # <br /> Service Station Systems (408) 971 -2445 <br /> Mailing Address <br /> 680 Quinn ave San Jose Ca, 95112 <br /> Name of UST Service Technician Performing the Certification (Print as shown on the ICC Certification) <br /> Brian McPheely <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 485184 8822062 11 /9/2019 <br /> Monitorin S stem Trainingand Certifications (List all applicable certifications. ) Expiration Date <br /> VR B36745 2/27/2020 <br /> VMI 111 /29/2019 <br /> Red Jacket 11 / 14/2019 <br /> ill . RESULTS OF TESTING 1 SERVICING <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. Y N NA <br /> Z Monitoring System Set-up ® Alarm Histo Report <br /> Was any monitoring equipment replaced? <br /> (If ° Yes, " identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) <br /> Was damage, debris, or liquid found inside any secondary containment systems? El © R <br /> (if "Yes, " describe what was found in section IV below.) <br /> Is all monitoring equipment operational per manufacturer's specifications? ® El El <br /> (if Woo " describe why in section IV below.) _ <br /> IV. COMMENTS <br /> If directed to use this section, describe how end when the issues were or will be corrected. <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the equipment identified in this document was inspectedlserviced in accordance with California Code of <br /> Regulations , Title 23 , Division 3 , Chapter 16, Section 2638 and all information contained herein is true and accurate. Attached to <br /> this certification is information (e.g . , manufacturers ' checklists , monitoring system set-up , alarm history report, etc .) necessary <br /> to verify that this information and the site plan showing the layout of UST system is complete and accurate. <br /> UST Service Technician Signature <br /> CERS = Caffomia Envh)nnwM Reporting System, 10 = Identification, ICC = Intemationd Code Council, Y = Yes, N = No, NA = Not Applicable <br />