My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
10878
>
2300 - Underground Storage Tank Program
>
PR0231598
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:16 PM
Creation date
6/11/2020 2:30:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231598
PE
2361
FACILITY_ID
FA0001146
FACILITY_NAME
MORADA CHEVRON FAST N EASY #60*
STREET_NUMBER
10878
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08607002
CURRENT_STATUS
01
SITE_LOCATION
10878 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for MORADA CHEVRON FAST N EASY#60* as of October 07, <br /> 2020. <br /> Open violations from May 28, 2020 inspection <br /> Violation#208-Failure to conduct the designated UST operator visual inspection at least once every 30 <br /> days. <br /> 1)OBSERVATION: Designated operator reports were not signed within the required time frame. <br /> -The designated operator reports were not signed by the owner/operator. <br /> REGULATORY GUIDANCE:Within 48 hours of the completion of the designated UST operator visual inspection, <br /> the designated operator shall sign and provide the owner or operator with a copy of the inspection report.Within <br /> 48 hours of being provided a signed copy of the report,the owner or operator shall provide a description of each <br /> corrective action taken or to be taken and shall sign and date the report, acknowledging the identified compliance <br /> issues. <br /> CORRECTIVE ACTION: Ensure all designated operator inspection reports are completed and signed within the <br /> required time frame in the future. <br /> 2)OBSERVATION:The designated operator inspections for the following months were performed more than 30 <br /> days after the previous inspection: <br /> - Initial inspection on 6/27/2019, next inspection performed on 7/29/2019(32 days) <br /> - Initial inspection on 8/22/2019, next inspection performed on 9/23/2019(32 days) <br /> - Initial inspection on 9/23/2019, next inspection performed on 10/28/2019(35 days) <br /> - Initial inspection on 12/18/2019, next inspection performed on 1/23/2020(36 days) <br /> - Initial inspection on 2/21/2020, next inspection performed on 3/23/2020(31 days) <br /> - Initial inspection on 4/20/2020, next inspection performed on 5/21/2020(31 days) <br /> REGULATION GUIDANCE: The designated operator visual inspections shall be conducted within 30 days or less <br /> of the previous inspection. <br /> CORRECTIVE ACTION: Ensure that all designated operator inspections are performed within the required time <br /> frames. <br /> 3)OBSERVATION:The designated operator failed to check and note the correct test dates for the monitoring <br /> system certification, spill container and secondary containment testing on the designated operator inspection <br /> reports. <br /> -Monitoring system certification and spill container testing was performed on 4/11/2019. <br /> -Secondary containment testing was performed on 5/24/2018. <br /> REGULATION GUIDANCE: During the inspection, the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and document the dates they were done. <br /> CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of <br /> the required information on the reports. <br /> 4)OBSERVATION:The designated operator failed to check and note all required items on the visual inspection <br /> reports.The incorrect and missing information included the following from the inspection reports: <br /> -The designated operator answered the question regarding sump sensor locations but did not list which sumps <br /> were visually inspected. <br /> -The designated operator documented visual inspections of the UDCs bur left the question regarding UDC sensor <br /> location blank. <br /> -The"N/NA" in sections VII through XI were not fully explained in section III of the report. <br /> -Missing CERS ID <br /> -Section V was missing UST owner/operator's response <br /> -According to the reports, overfill prevention equipment inspection was said to be conducted on 11/26/2018 but <br /> there were no notifications or test results sent to EHD, no work orders or test results found onsite indicating overfill <br /> prevention testing was completed. <br /> Page 6 of 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.