My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
25651
>
2300 - Underground Storage Tank Program
>
PR0231628
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:16 PM
Creation date
6/11/2020 3:03:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231628
PE
2361
FACILITY_ID
FA0003835
FACILITY_NAME
SMK CHEVRON
STREET_NUMBER
25651
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
Zip
95220
APN
00514120
CURRENT_STATUS
01
SITE_LOCATION
25651 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br />COUNTY— <br />Environmental <br />OU 1TY <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />SMK CHEVRON <br />25651 N HWY 99, ACAMPO <br />May 04, 2020 <br />Other Violations <br />2010 1 <br />See below <br />Unlisted General violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />106 <br />CCR 2632(d)(2), 2634(e) Failed to have an approved UST response plan. <br />OBSERVATION: The response plan is not current and/or not approved by the EHD. <br />No response plan was submitted in CERS. <br />REGULATION GUIDANCE: The response plan must be uploaded to the California Environmental Reporting System <br />(CERS). <br />CORRECTIVE ACTION: Immediately log into CERS, upload the completed form, and submit for review by the EHD. <br />This is a minor violation. <br />107 <br />CCR 2632(d), 2641(h), 2711(a) Plot plan/site map not submitted or failed to completely show where monitoring is <br />performed. <br />OBSERVATION: An accurate UST Monitoring Site Plan was not submitted. No moitoring site plan was submitted <br />in CERS. <br />REGULATION GUIDANCE: A site plan must be submitted identifying the locations where monitoring will be <br />performed. The site plan must show the general layout of tanks and piping and clearly identify locations of the <br />following equipment, if installed: 1) monitoring system control panels; 2) in -tank liquid level probes (if used for leak <br />detection); 3) devices monitoring tank annular spaces or vault; 4) devices monitoring product piping; 5) devices <br />monitoring fill piping; 6) devices monitoring vent piping; 7) devices monitoring vapor recovery piping; 8) devices <br />monitoring vent/transition sumps; 9) devices monitoring under -dispenser containment; 10) line leak detectors; and <br />11) devices monitoring any other secondary containment areas. <br />CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site Plan. <br />This is a minor violation. <br />115 <br />CCR 2715(a)(1)(B), 2715(a)(3) "Designated Underground Storage Tank Operator Identification Form" not submitted <br />within 30 days. <br />OBSERVATION: No designated operator identification form was submitted in CERS. <br />REGULATION GUIDANCE: The owner or operator shall submit a "Designated Underground Storage Tank Operator <br />Identification Form" no later than 30 days after any change in the designated UST operator(s). <br />CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov and upload the notification identifying all the designated operators for this facility. <br />This is a minor violation. <br />FA0003835 PR0231628 SCO01 05/04/2020 <br />EHD 23-01 Rev. 9/20/2019 Page 4 of 6 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.