COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
4075
>
2300 - Underground Storage Tank Program
>
PR0231667
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2020 4:37:26 PM
Creation date
6/11/2020 3:47:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231667
PE
2361
FACILITY_ID
FA0002121
FACILITY_NAME
JAMAR SERVICE
STREET_NUMBER
4075
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
15726411
CURRENT_STATUS
01
SITE_LOCATION
4075 E MAIN ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited : Chapter 6 . 7 , Health and Safety Code ; Chapter 16 , Division 3 , Title 23 , California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility <br /> Kinma. JAMAR SVC Bldg . No. : <br /> Site <br /> Arldraccm 4075 EAST MAIN STREET City: STOCKTON Zip: 95205 <br /> Facility Contact <br /> Pp.r.cnn4 JASON Contact Phone No. : (209) 462-4685 <br /> Make/Model of Monitoring System : VEEDER ROOT TLS 350 Date of Testing/Servicing : 5117118 <br /> B . Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment ins ected/serviced : <br /> Tank ID : 87 Tank ID : 91 <br /> E In-Tank Gauging Probe . Model : MAG 1 E In-Tank Gauging Probe . Model: MAG 1 <br /> E Annular Space or Vault Sensor. Model : 409 E Annular Space or Vault Sensor. Model : SPILT 187 <br /> E Piping Sump / Trench Sensor(s) . Model : 208 E Piping Sump / Trench Sensor(s) . Model : 208 <br /> ❑ Fill Sump Sensor(s) . Model : ❑ Fill Sump Sensor(s) . Model : <br /> E Mechanical Line Leak Detector. Model : PE PETRO E Mechanical Line Leak Detector. Model: 99 LD 2000 <br /> ❑ Electronic Line Leak Detector. Model : ❑ Electronic Line Leak Detector. Model : <br /> E Tank Overfill / High-Level Sensor. Model : FLAPPER E Tank Overfill / High- Level Sensor. Model : FLAPPER <br /> El (specify equipment type and model in Section E on Page 2) . [3 Other (specify equipment type and model in Section E on Page 2) . <br /> Tank ID : NA Tank ID : NA <br /> ❑ In-Tank Gauging Probe . Model : ❑ In-Tank Gauging Probe. Model : <br /> ❑ Annular Space or Vault Sensor. Model : ❑ Annular Space or Vault Sensor. Model : <br /> ❑ Piping Sump / Trench Sensor(s) . Model : ❑ Piping Sump / Trench Sensor(s) . Model: <br /> ❑ Fill Sump Sensor(s) . Model : ❑ Fill Sump Sensor(s) . Model : <br /> ❑ Mechanical Line Leak Detector. Model : ❑ Mechanical Line Leak Detector. Model : <br /> ❑ Electronic Line Leak Detector. Model : ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill / High- Level Sensor. Model : ❑ Tank Overfill / High-Level Sensor. Model : <br /> ❑ Other (specify equipment type and model in Section E on Page 2) . ❑ Other (specify equipment type and model in Section E on Page 2) . <br /> Dispenser ID : 1 -2 Dispenser ID : 34 <br /> ❑ Dispenser Containment Sensor(s) . Model : ❑ Dispenser Containment Sensor(s) , Model: <br /> E Shear Valve(s) . E Shear Valve(s) . <br /> E Dispenser Containment Float(s) and Chain (s) . E Dispenser Containment Float(s) and Chain (s) . <br /> Dispenser ID : 5-6 Dispenser ID : 7-8 <br /> ❑ Dispenser Containment Sensor(s) . Model : ❑ Dispenser Containment Sensor(s) . Model : <br /> E Shear Valve(s) . E Shear Valve(s) . <br /> E Dispenser Containment Float(s) and Chain (s) . E Dispenser Containment Float(s) and Chain (s) . <br /> Dispenser ID : NA Dispenser ID : NA <br /> ❑ Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s) . Model : Sensor(s) . Model : <br /> ❑ Shear Valve(s) . ❑ Shear Valve(s) . <br /> ❑ Dispenser Containment Float(s) and Chain (s) . ❑ Dispenser Containment Float(s) and Chain (s) . <br /> `If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines . Attached to this Certification is information (e.g . manufacturers' checklists) necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br /> copy of the report; (check all that apply) : E System set- up ® Alarm history report <br /> Technician Name (print) : FELIX RAMIREZ Signature: <br /> Certification No. : B34976 License No: 8883072- UT 08- 1740 OTTL <br /> Testing Company Name: AFFORDA-TEST Phone No . (209) 744-0113 <br /> Testing Company Address : 416 2nd STREET GALT CA 95632 Date of Testing/Servicing : 05- 17- 18 <br /> Monitoring System Certification Page 1 of 4 2/21 /07 <br />