Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page 1 of 6) <br /> This form must be used to document testing and servicing of underground storage tank(UST)monitoring equipment. A copy of this form <br /> must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local agency regulating the <br /> USTs within 30 days of the date of the monitoring system certification. <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10181249 02/20/2020 <br /> Business Name(Same as Facility Name or DBA—Doing Business As.) TBuilding# <br /> ARP Mini Mart Mobil <br /> Business Site Address City ZIP Code <br /> 25775 S. Patterson Pass Rd. Trac 95376 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone# <br /> Diamond Petroleum Services, Inc. (925)470- 0803 Ext. <br /> Mailing Address <br /> 3619 King Ct. Antioch, CA 94509 <br /> Name of UST Service Technician Performing the Certification(Print as shown on the iCC Certification.) <br /> Guadalupe Sanchez <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 1005444 5250451 04/05/2021 <br /> Monitoring System Training and Certifications List at/applicable cerfifrcations. Expiration Date <br /> Veeder Root A30138 10/05/2021 <br /> VMI Va orless LDT-890 Tester#4068 06/12/2021 <br /> III. RESULTS OF TESTING/SERVICING <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. Y N NA <br /> ®Monitoring System Set-up ®Alarm History Report <br /> Was any monitoring equipment replaced? <br /> (if'Yes,"identify the specific devices replaced and list the manufacturer and model for all replacement parts in section iV below.) <br /> Was damage,debris,or liquid found inside any secondary containment systems? ❑ ® 0 <br /> (If"Yes,"describe what was found in section IV below.) <br /> Is all monitoring equipment operational per manufacturer's specifications? E ❑ 0 <br /> (if"No,"describe why in section IV below.) <br /> IV. COMMENTS <br /> If directed to use this section,describe how and when the issues were or will be corrected. <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the equipment identified in this document was inspectediserviced in accordance with California Code of <br /> Regulations,title 23,division 3,chapter 16,section 2638 and all information contained herein Is true and accurate. Attached to <br /> this certification is information(e.g.,manufacturers'checklists,monitoring system set-up,alarm history report,etc.)necessary <br /> to verify that this information and the site plan showing the layout of UST system is complete and accurate. <br /> UST Service Technician Signature / /l <br /> rFRc=r-al r-m,r M RorvvHnn Sliatsxn in= ; ur.a r rawip rn hill v=Voa N=Nn Ne=W*annfir-ANP <br />