My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2020 1:06:03 PM
Creation date
6/11/2020 3:55:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SUBMERSIBLE PUMPING SYSTEMS <br /> Franklin Fueling Systems I SUBMERSIBLE TURBINE PUMPS <br /> Specifications <br /> • Variable speed models are available in variable Power Requirements <br /> lengths only. .Variable speed pumps can only be controlled by a <br /> • Check valve:23/<"diameter fluorocarbon seal MagVFC—variable frequency controller: <br /> constructed with cast aluminum body and steel <br /> backing washer. •VS2 models can operate with single-or three-phase <br /> incoming power supply to the MagVFC' <br /> • Pressure relief valve: available in four pressure relief •VS4 models require three-phase incoming power <br /> settings,integral to check valve.Standard model supply to the MagVFC' for proper operation. <br /> relieves at 40 psi and resets above 35 psi. <br /> •Syphon:venturi-type syphon primer supplied with • Incoming power supply to the MagVFC'"can be <br /> every submersible.Syphon check valve and 200-250 VAC,50 or 60 Hz. <br /> secondary syphon sold separately. •MagVFC' outputs a three-phase,variable frequency <br /> •Air eliminator:every submersible includes a tank return <br /> signal,valid for FE Petro'"variable speed pumps only. <br /> path with one-way check valve to provide active air •VS2 max. motor draw:9 Amps. <br /> elimination. •MagVFC' max. line draw:20 Amps. <br /> • Electrical disconnect: electrical yoke for positive <br /> contractor disconnect during service. Liquid Compatibility <br /> Pump Motor • Max. liquid viscosity: 70 SSU at 60 OF (15 OC). <br /> •2 Hp or 4 Hp,variable speed,two-stage centrifugal •STP variable speed models are UL and cUL listed for <br /> type pump motor with integral,automatic, thermal fuel mixtures containing up to 10%ethanol, and 20% <br /> overload protection. MTBE, 20% ETBE or 17%TAME with gasoline. <br /> • Max.flow:VS2= 1 10 gpm,VS4= 140 gpm. • IST variable speed models are UL and cUL listed for fuel <br /> mixtures containing diesel fuel with up to 20% <br /> • Max. pressure:selectable operating pressure on biodiesel, 100%biodiesel, up to 85%ethanol with <br /> MagVFC' between 24 psi and 42 psi deadhead. gasoline, and 20%MTBE,20%ETBE or 17%TAME with <br /> •Available with MagShell—which results in 45% gasoline. <br /> increased flow area around motor. .All variable speed (non-AG) models can also be used <br /> Approvals with diesel fuels,fuel oils, kerosene,Avgas and jet fuels <br /> in a non-gelled pourable state. <br /> •cULus listed. •All wetted elastomers are made of a high grade, <br /> •Consult factory for applicable approvals. fluorocarbon compound. <br /> Quality Certification <br /> • Franklin Fueling Systems is an ISO 9001 Certified <br /> Manufacturer. <br /> 2 hp Variable Speed Turbine Performance Chart 4 hp Variable Speed Turbine Performance Chart <br /> 140 ------ --------------------- ------ -------------- ------ ------------- <br /> ----- 140 ----------------- ---------------------------- ----- ---------- ----- ----- ------ <br /> 130 ------ ------------- ------ ------ ------------ - <br /> _____ <br /> Two MVS2,Manifolded 2 hp --- ----- ----- ---------- ----- -- <br /> ----------- <br /> --- -- <br /> - ----- -- Two MVS4,Manifolded 4 h <br /> 120 ------ -------- - --------- ----`- ------------- MagShelr"Variable Speed _ <br /> Pumps 120 ---------- ----- --- ----- ---------- �'�;- ---- MagShelf"Variable Speed _ <br /> Pumps <br /> 110 ------ -------- ----- ------ ------ ------ ----- -------- ------ 110 -- - --- ---------- - --- ----------- <br /> 100 <br /> ---- -----100 ------ -------- ----- -- --- -------------------- <br /> ------ ----- -------- ------ 100 - - -- ---------- ----- ------------------ --- ------------ <br /> 90 <br /> ---- -----90 - <br /> 80 ------ -------- ----- ------ --------------------- ------ ----- ---_____ ______ LL <br /> cc 80----------------- ----- ----- ---------- ----- <br /> 70 ___ One MVS2,2 hp MagShell^ _ ____ ______________ ______ _ %_ ________ ______ o 70 __ _________ _____ _____ ______,,-,_ _ ___ _____ _____ <br /> = Variable Speed Pump • One MVS4 4 hp MagShell'" <br /> 60 ___ ___ __ ______________ ______ ----- ------ 6 60 Vanable Speed Pump __ __ _ ---_ _____ __________ ___ _____ _____. <br /> p _ <br /> O ,` o <br /> 50 ______ ______________ ______ ____ _ ______________ ______ __________%___ ______ 50 <br /> 40 ------ --------------------- ------ -------------- ------ - <br /> ------------ ------ <br /> 30 ------ -------------- ------ ------ ------------- - <br /> 20 ------ --------------------- ------ -- ----------- - <br /> 20 ---------- ----- ----- ----------- <br /> 10 ------ -------------- ------ --------------------- <br /> ----- -------------- - <br /> ----- -------------- ------ 10 ---------- ----- ----- ----- ---------- ----- ----- ---------- ----- ----- ------ <br /> 0 0 <br /> 0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 <br /> Flow in Gallons per Minute(gpm) <br /> Flow in Gallons per Minute(gpm) <br />
The URL can be used to link to this page
Your browser does not support the video tag.