My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
STIMSON
>
2000
>
2300 - Underground Storage Tank Program
>
PR0231732
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2021 9:31:05 AM
Creation date
6/11/2020 3:56:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231732
PE
2361
FACILITY_ID
FA0003648
FACILITY_NAME
STKN ARMY AVIATION SUPP FACILITY*
STREET_NUMBER
2000
STREET_NAME
STIMSON
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
17726004
CURRENT_STATUS
01
SITE_LOCATION
2000 STIMSON RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
90
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br /> UNDERGROUND STORAGE TANK JUL ,1 ) 2NO <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection ftNWVW4ipn,,, <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10181267 10/5/2018 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> CALIFORNIA NATIONAL GUARD - STOCKTON AIRPORT <br /> Business Site Address City ZIP Code <br /> 2000 STINSON RD. � STOCKTON, CA 95206 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> FELIX RAMIREZ 1 (209) 744-0112 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 08-1740 5-31-18 8883072-UT 11/22/2018 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> OPW 104634 3-14-20 <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑x Manufacturer Guidelines(Specify): <br /> Used: OPW <br /> ❑ Industry Code or Engineering Standard(Specify): <br /> ❑Engineered Method (Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. --T#-of Attached Pages 2 <br /> TANK ID: (By tank number,stored product,etc.) AV Gas <br /> What is the tank inside diameter?(Inches) 127.5 <br /> Is the fill piping secondarily contained? ❑Yes I]No ❑Yes ❑ No ❑Yes ❑No ❑Yes ❑No <br /> Is the vent piping secondarily contained? ❑Yes I] No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> Overfill Prevention Equipment Manufacturer(s) OPW <br /> What is the overfill prevention equipment response El Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow <br /> when activated? <br /> ❑ <br /> (Check all that apply.) Restricts Flow El Restricts Flow El Restricts Flow EI Restricts Flow <br /> ❑AN Alarm ❑AA/Alarm ❑AN Alarm ❑AIV Alarm <br /> Are flow restrictors installed on vent piping? ❑Yes Z No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑ No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(Inches from bottom of tank.) 115 <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 93% <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑Yes ❑Yes ❑Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑No(Specify in V.) ❑ No(Specify in V.) ❑No(Specify in V.) ❑No(Specify in V) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results X Pass El Fail ElPass ElFail ElPass [J—F-aiilElPass El Fail <br /> V. COMMENTS <br /> Any items marked"Fail'must be explained in this section. Any additional comments may also be provided here. <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations,Title 23, <br /> Division 3,Chapter 16,Section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than this form accommodates,additional copies of this page may be attached. <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,AN=Audible and Usual <br />
The URL can be used to link to this page
Your browser does not support the video tag.