Laserfiche WebLink
Specifications 1.7 Environmental Conditions <br /> An ANSUL R-102 Fire Suppres,ion System shall be furnished. I 1.7.1 The R-102 system shall be capable of operating <br /> The system shall be capable of protecting all hazard areas associ- , within a temperature range of 32 F to 130 F <br /> ated with cooking equipment. (0°C to 54°C). <br /> 1.0 GENEPAL 2,0 PRODUCT <br /> 1.1 References 2.1 Manufacturer <br /> 1.1.: Underwriters Laboratories,Inc.(UL) ' 2.1.1 Tyco Fire Protection Products,One Stanton <br /> 1.1.1.1 UL Standard 1254 Street,Marinette,Wisconsin 54143-2542, <br /> 1.1.1.2 UL Standard 300 Telephone(715)735-7411. <br /> 1.1.2 Underwriters Laboratories of Canada(ULC) 2.2 Components <br /> 1.1.2.1 ULC/ORD-C 1254.6 i 2.2.1 The basic system shall consist of an AUTOMAN <br /> 1 regulated release assembly which includes a <br /> 1.1.3 National Fire Protection Association(NEPA) ( regulated release mechanism and a wet chemical <br /> 1.1.3.1 NFPA 96 l storage tank housed within a single enclosure. <br /> 1.1.3.2 NFPA 17A I Nozzles,blow-off caps,detectors,cartridges, <br /> 1.2 Submittals ( agent,fusible links,and pulley elbows shall be <br /> supplied in separate packages in the quantities <br /> 1.2.1 Submit two sets of manufacturers data sheets j needed for fire suppression system arrange- <br /> 1.2.2 Submit two sets of piping design drawings i ments.Additional equipment shall include <br /> 1.3 System Description: remote manual pull station,mechanical and <br /> j <br /> electrical gas valves,and electrical switches for <br /> 1.3.1 The system shall be an automatic fire suppres- i automatic equipment and gas line shut-off,and <br /> sion system using a wet chemical agent for building fire alarm control panel interface. <br /> cooking grease related fires. i <br /> 2.2.2 Wet Chemical Agent:The extinguishing agent <br /> 1.3.2 The system shall be capable of suppressing fires shall be a specially formulated,aqueous solution <br /> in the areas associated with ventilating equip- j of organic salts with a pH range between 7.7— <br /> ment including hoods,ducts,plenums,and filters i 8.7,designed for flame knockdown and foam <br /> as well as auxiliary grease extraction equipment. i securement of grease related fires. <br /> The system shall also be capable of suppressing <br /> fires in areas associated with cooking equipment, 2.2.3 Agent Tank:The agent tank shall be installed in <br /> such as fryers;griddles and range tops;upright, a stainless steel enclosure or wall bracket.The <br /> natural charcoal,or chain-type broilers;electric, tank shall be constructed of stainless steel.Tanks <br /> lava rock,mesquite or gas-radiant char-broilers; j shat{be available in two sizes;1.5 gallon(5,7 L) <br /> and woks. and 3.0 gal(11.4 Q.The tank shall have a working <br /> pressure of 110 psi(7.6 bar),a test pressure of <br /> 1.3.3 The system shall be the pre-engineered type 330 psi (22.8 bar),and a minimum burst pressure <br /> having minimum and n'raximum guidelines i of 660 psi(45.5 bar).The tank shall include an <br /> established by the manufacturer and listed by adaptor/tube assembly containing a burst disc <br /> Underwriters Laboratories(UUULC). union. <br /> 1.3.4 The system shall be installed and serviced by ? 2,2,4 Regulated Release Mechanism:The regulated <br /> personnel trained by the manufacturer. release mechanism shall be a spring-loaded, <br /> 1.3.5 The system shall be capable of protecting mechanical/pneumatic type capable of provid- <br /> cooking appliances by utilizing either dedicated j ing the expellant gas supply to one or two agent <br /> appliance protection and/or overlapping appli- tanks depending on the capacity of the gas <br /> encs protection. j cartridge used or three 3.0 gallon(11.4 L)agent <br /> i storage tanks in certain applications.It shall <br /> 1.4 Quality Control contain a factory installed regulator deadset at <br /> 1.4.1 Manufacturer:The R-102 Restaurant Fire 110 psi(7.6 bar)with an external relief of approx- <br /> Suppression System shall be manufactured by a I imately 180 psi(12.4 bar). <br /> company with at least forty years experience in It shall have the following actuation capabili- <br /> the design and manufacture of pre-engineered ties:automatic actuation by a fusible link detec- <br /> fire suppression systems.'The manufacturer shall tion system and remote manual actuation by a <br /> he ISO 9001 registered. I mechanical pull station. <br /> 1.4.2 Certificates:The wet agent shall be a specially ; The regulated release mechanism shall contain <br /> formulated,aqueous solution of organic salts a release assembly,regulator,expellant gas <br /> with a pH range between 7.7—8 7,designed hose,and agent storage tank housed in a stain- <br /> for flame knockdown and foam securement of I less steel enclosure with cover.The enclosure <br /> grease-related fires. ; shall contain knock-outs for 1/2 in.conduit.The <br /> cover shall contain an opening for a visual status <br /> 1.5 Warranty,Disclaimer,and Limitations indicator. <br /> 1.5.1 The pre-engineered restaurant fire suppression It she()be compatible with mechanical <br /> system components shall be warranted for five p' gas shut- <br /> off devices;or,when equipped with a field or <br /> years from date of delivery against defects in I fa�tury-installed switch(es),it shall be con, pat- <br /> workmanship and material. ible with ciectric gas line or appliance shut-off <br /> 1.6 Delivery devices,or connections to a building fire alarm <br /> 1.6,1 Packaging:All system components shall be control panel. <br /> securely packagers to provide protection during <br /> shipment. <br />